BS EN 61184:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Bayonet lampholders
Hardcopy , PDF
03-10-2022
English
21-11-2017
Committee |
CPL/34/1
|
DevelopmentNote |
Supersedes 95/211062 DC and 99/245234 DC. (11/2001) Supersedes 03/301475 DC. (11/2005) Supersedes 07/30169008 DC. (04/2009) Supersedes 10/30215790 DC. (10/2011) Supersedes 16/30337907 DC. (11/2017)
|
DocumentType |
Standard
|
Pages |
76
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This document applies to bayonet lampholders B15d and B22d for connection of lamps and semi-luminaires to a supply voltage of 250V. This document also covers lampholders which are integral with a luminaire or intended to be built into appliances. It covers the requirements for the lampholder only. For all other requirements, such as protection against electric shock in the area of the terminals, the requirements of the relevant appliance standard are observed and tested after building into the appropriate equipment, when that equipment is tested according to its own standard. Lampholders for use by luminaire manufacturers only are not for retail sale. Where lampholders are used in luminaires, their maximum operating temperatures are specified in IEC60598‑1 . B15d denotes the cap/holder fit as defined by IEC60061‑1 , sheet 7004-11 and IEC60061‑2 , sheet 7005-16 with the corresponding gauges. B22d denotes the cap/holder fit as defined by IEC60061‑1 , sheet 7004-10 and IEC60061‑2 , sheet 7005-10 with the corresponding gauges.
Standards | Relationship |
NBN EN 61184 : 2010 AMD 1 2011 | Identical |
IEC 61184:2017 | Identical |
UNE-EN 61184:2011 | Identical |
EN 61184:2017 | Identical |
NF EN 61184 : 2008 AMD 1 2011 | Identical |
I.S. EN 61184:2017 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 60838-1:2016+AMD1:2017 CSV | Miscellaneous lampholders - Part 1: General requirements and tests |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60399:2004/A1:2008 | BARREL THREAD FOR LAMPHOLDERS WITH SHADE HOLDER RING |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60399:2004+AMD1:2008 CSV | Barrel thread for lampholders with shade holder ring |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60061-4:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 4046-4:2002 | Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.