BS EN 61076-3-114:2009
Current
The latest, up-to-date edition.
Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for.protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 11 related to IEC 61076-3-106. Bayonet coupling type
Hardcopy , PDF
English
30-09-2009
INTRODUCTION
1 General data
1.1 Scope
1.2 Normative references
2 Terms and definitions
3 Dimensional information
3.1 Common features
3.2 General
3.3 Contact arrangement of all connector types
3.4 IP65 and IP67 sealing
3.5 Industrial IEC 60603-7 variant 11 - Bayonet coupling
3.5.1 Industrial IEC 60603-7 variant 11, fixed connectors
3.5.2 Industrial IEC 60603-7 variant 11, free connectors
3.6 Termination and mounting information
3.7 General
3.8 Mounting information for variant 11, fixed connector
3.9 Cap for fixed connector
3.10 Cap for free connector
4 Gauges
4.1 Connectors, IEC 60603-7 interface
5 Characteristics
5.1 Climatic category
5.2 Electrical
5.2.1 Clearance and creepage distances
5.2.2 Voltage proof
5.2.3 Current-derating diagram
5.2.4 Mating cycles with power applied
5.2.5 Initial contact resistance
5.2.6 Input-to-output resistance
5.2.7 Resistance unbalance
5.2.8 Initial insulation resistance
5.3 Transmission characteristics
5.3.1 General
5.3.2 Mechanical operation
5.3.3 Effectiveness of connector coupling devices
transversal
5.3.4 Effectiveness of connector coupling devices
5.3.5 Separation and engagement forces
6 Test schedule
6.1 General
6.2 Test procedures and measuring methods
6.3 Preconditioning
6.4 Wiring and mounting of specimens
6.4.1 Wiring
6.4.2 Mounting
6.5 Arrangement for contact resistance test
6.6 Arrangement for dynamic stress tests (test phase AP2)
6.7 Basic (minimum) test schedule
6.8 Full test schedule
6.8.1 Test preliminary group P
6.8.2 Test group P
6.8.3 Test group AP
6.8.4 Test group BP
6.8.5 Test group CP
6.8.6 Test group DP
6.8.7 Test group EP
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Specifies protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments.
Committee |
EPL/48
|
DevelopmentNote |
Supersedes 06/30148019 DC. (09/2009)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 61076-3-114:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
Standards | Relationship |
IEC 61076-3-114:2009 | Identical |
EN 61076-3-114 : 2009 | Identical |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
EN 60603-7-7:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 60603-7-2:2010 | Connectors for electronic equipment - Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
MIL-DTL-26482 Revision H:2007 | Connectors, Electrical, Circular, Miniature, Quick Disconnect, Environment Resisting, Receptacles and Plugs, General Specification for |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
IEC 60603-7-3:2010 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60603-7-7:2010 | Connectors for electronic equipment - Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.