BS EN 61048 : 2006
Current
The latest, up-to-date edition.
AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS
Hardcopy , PDF
English
01-01-2006
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Marking
7 Terminations
8 Creepage distances and clearances
9 Voltage rating
10 Fuses
11 Discharge resistors
12 Testing sequence
13 Sealing and heating test
14 High-voltage test
15 Resistance to adverse operating conditions
16 Resistance to heat, fire and tracking
17 Self-healing test
18 Destruction test
Annex A (normative) - Test voltage
Annex B (normative) - Temperature adjustment of test
Enclosure
Annex C (normative) - Test for conformity of manufacture
Annex D (informative) - Guide to calculating equipment
settings for tests in 15.2 and 18.1.3
Annex E (normative) - Additional requirements for built-in
capacitors having an insulation equivalent to
double or reinforced insulation
Annex F (informative) - Information for luminaire design
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Bibliography
Gives the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2,5 kVAr, and not less than 0,1 [MU]MF having a rated voltage not exceeding 1000 V which are intended for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3000 m.
Committee |
CPL/34/3
|
DevelopmentNote |
Supersedes 89/28666 DC, 94/201613 DC and 97/205733 DC. (04/2005) Together with BS EN 61049, it supersedes BS 4017(1979). (12/2005) 2006 Edition Re-Issued in February 2016 & incorporates AMD 1 2016. 2006 Edition remains active and will be withdrawn on 11/08/2018. Supersedes 12/30263952 DC. (03/2016)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 61048:2006/A1:2016 | Identical |
NBN EN 61048 : 2006 AMD 1 2016 | Identical |
UNE-EN 61048:2007 | Identical |
IEC 61048:2006+AMD1:2015 CSV | Identical |
I.S. EN 61048:2006 | Identical |
NF EN 61048 : 2006 AMD 1 2016 | Identical |
DIN EN 61048 : 2016 | Identical |
BS EN 61049:1993 | Specification for capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
EN 60192:2001 | Low pressure sodium vapour lamps - Performance specifications |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
EN 61347-2-9:2013 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
IEC 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 61167:2015 | Metal halide lamps - Performance specification |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
EN 61049:1993 | Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements |
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60901:1996/A6:2017 | SINGLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS (IEC 60901:1996/A6:2014, MODIFIED) |
EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
ISO 4046-4:2002 | Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 61347-2-8:2000+AMD1:2006 CSV | Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.