Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 60968:2015

Current

Current

The latest, up-to-date edition.

Self-ballasted fluorescent lamps for general lighting services. Safety requirements

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2015

$520.16
Including GST where applicable

Committee
CPL/34/1
DevelopmentNote
Renumbers and supersedes BS 7173(1989). 2000 version incorporates amendment 10815 to BS 7173(1989). Supersedes 85/26674 DC and 97/209078 DC. (01/2006) Supersedes 11/30258020 DC. (03/2013) Supersedes 12/30273415 DC. (07/2015)
DocumentType
Standard
Pages
36
PublisherName
British Standards Institution
Status
Current
Supersedes

This International Standard specifies the safety and interchangeability requirements, together with the test methods and conditions required to show compliance of tubular fluorescent lamps with integrated means for controlling starting and stable operation (self-ballasted fluorescent lamps). These lamps are intended for domestic and similar general lighting purposes, having a rated voltage of 50V to 250V, having a rated frequency of 50Hz or 60Hz and having IEC60061‑1 compliant caps. For a cap-holder system not specifically mentioned in this standard, the relevant information on safety related tests provided by the manufacturer will apply. The requirements of this standard relate only to type testing. Recommendations for whole product testing or batch testing are given in AnnexA. This part of the standard covers photobiological safety according to IEC62471 and IECTR62471‑2 . Blue light and infrared hazards are below the level which requires marking.

Standards Relationship
UNE-EN 60968:2015 Identical
DIN EN 60968 : 2016 Identical
I.S. EN 60968:2015 Identical
SN EN 60968 : 2013 AMD 11 2014 Identical
EN 60968:2015 Identical
NF EN 60968 : 2016 Identical
IEC 60968:2015/COR1:2015 Identical
EN 61587-1:2007 Identical

IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes
IEC 60061-3:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
IEC TR 62471-2:2009 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
EN 61199:2011/A2:2015 SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61199:2011/A2:2014)
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV Single-capped fluorescent lamps - Safety specifications
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV Single-capped fluorescent lamps - Performance specifications
EN 60360:1998 Standard method of measurement of lamp cap temperature rise
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC 60061-1:2005 CSV Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
IEC 62471:2006 Photobiological safety of lamps and lamp systems
EN 60901:1996/A6:2017 SINGLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS (IEC 60901:1996/A6:2014, MODIFIED)
ISO 4046-4:2002 Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60432-1:2000/A2:2012 INCANDESCENT LAMPS - SAFETY SPECIFICATIONS - PART 1 - TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES (IEC 60432-1:1999/A2:2011)
IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
EN 62471:2008 Photobiological safety of lamps and lamp systems
IEC 60360:1998 Standard method of measurement of lamp cap temperature rise
EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more