BS EN 60811-513:2012

Current

Current

The latest, up-to-date edition.

Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Methods specific to polyethylene and polypropylene compounds. Wrapping test after conditioning

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2012

$268.61
Including GST where applicable

1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Provides procedures for a wrapping test after conditioning at elevated temperature.

Committee
GEL/20/17
DevelopmentNote
Together with BS EN 60811-100, BS EN 60811-407, BS EN 60811-408, BS EN 60811-410, BS EN 60811-510, BS EN 60811-512, it supersedes BS EN 60811-4-2. Supersedes 09/30193067 DC. To be read in conjunction with BS EN 60811-100. (08/2012)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Current
Supersedes

This Part 513 of IEC 60811 gives procedures for a wrapping test after conditioning at elevated temperature. This test method applies specifically to polyethylene and polypropylene insulation.

This test is intended for samples from filled cables of polyolefin insulation having a wall thickness of less than or equal to 0,8 mm.

Standards Relationship
IEC 60811-513:2012 Identical
EN 60811-513:2012 Identical

IEC 60811-601:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds
IEC 60811-4-2:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more