INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Annex A (informative) - Principle of operation of
        a typical machine for preparing test pieces
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Provides the procedure for determining the mechanical properties, which typically applies to cross-linked and thermoplastic compounds used for insulating and sheathing materials.

Committee
GEL/20/17
DevelopmentNote
Together with BS EN 60811-100, BS EN 60811-201, BS EN 60811-202, BS EN 60811-203, it supersedes BS EN 60811-1-1. Supersedes 09/30193015 DC. To be read in conjunction with BS EN 60811-100. (08/2012)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
IEC 60811-501:2012 Identical
EN 60811-501:2012 Identical

BS 7889:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations
BS 7846:2015 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
15/30301501 DC : 0 BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION
BS 7912(2012) : 2012 POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV)
BS 6724:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
15/30301742 DC : 0 BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS
BS 7211:2012 Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire
BS 5467:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification
15/30301443 DC : 0 BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION
BS 8573:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire
BS 6004:2012 Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting

IEC 60811-203:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
IEC 60811-401:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 60811-202:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath
IEC 60811-606:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density
EN 60811-404:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
IEC 60811-404:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
EN 60811-203:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 60811-201:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
EN 60811-606:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.