BS EN 60811-4-1:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Insulating and sheathing materials of electric and optical cables. Common test methods Methods specific to polypropylene and polypropylene compounds. Resistance to environmental stress cracking. Measurement of the melt flow index. Carbon black and/or mineral filter content measurement in PE by direct combustion. Measurement of carbon black content by TGA. Assessment of carbon black dispersion in polyethylene using a microscope
Hardcopy , PDF
31-07-2012
BS EN 60811-511:2012
BS EN 60811-100:2012
BS EN 60811-607:2012
BS EN 60811-406:2012
BS EN 60811-605:2012
English
02-09-2004
1 General
1.1 Scope
1.2 Normative references
2 Terms and definitions
3 Test values
4 Applicability
5 Type tests and other tests
6 Pre-conditioning
7 Median value
8 Resistance to environmental stress cracking
8.1 General
8.2 Apparatus
8.3 Preparation of the test sheets
8.4 Conditioning of the test sheets
8.5 Visual examination of the test sheets
8.6 Test procedure
8.7 Evaluation of results
8.8 Summary of test conditions and requirements for
procedures A and B
9 Wrapping test after thermal ageing in air
10 Measurement of the melt flow index
10.1 General
10.2 Apparatus
10.3 Test samples
10.4 Cleaning and maintenance of the apparatus
10.5 Method A
10.6 Method C
11 Carbon black and/or mineral filler content measurement
in polyethylene - Direct combustion method
11.1 Sampling
11.2 Test procedure
11.3 Expression of results
12 Thermo gravimetric analysis of the carbon black content
in polyolefine compounds
12.1 Principle
12.2 Reagents
12.3 Apparatus
12.4 Procedure
13 Test for the assessment of carbon black dispersion in
polyethylene
13.1 General
13.2 Procedure
13.3 Expression of results
13.4 Requirements
Annex A (informative) Tools and reagents
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric and optical fibre cables for power distribution and telecommunications, including cables used on ships and in offshore applications.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes BS 6469-4.1(1992). Supersedes 02/205374 DC. (09/2004)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric and optical fibre cables for power distribution and telecommunications, including cables used on ships and in offshore applications. These test methods apply specifically to PE and PP compounds, including cellular compounds and foam skin for insulation. The principal changes with respect to the previous edition are listed below: a) the wrapping test after thermal ageing in air is deleted from this part of IEC 60811. It is now given only in IEC 60811-4-2; b) a thermogravimetric method is added for determination of carbon black content; c) a method is introduced for assessment of carbon black dispersion.
Standards | Relationship |
I.S. EN 60811-4-1:2004 | Identical |
EN 60811-4-1:2004 | Identical |
SN EN 60811-4-1 : 1995 | Identical |
NF EN 60811-4-1 : 2004 | Identical |
UNE-EN 60811-4-1:2005 | Identical |
IEC 60811-4-1:2004 | Identical |
DIN EN 60811-4-1 : 2005 | Identical |
BS 7870-5:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
11/30214055 DC : 0 | BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL |
BS 7870-4.11:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 33 kV lead sheathed cables - Single core 33 kV lead sheathed cables |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
BS 7870-4.10:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV Single-core 11 kV and 33 kV cables - Single core 11 kV and 33 kV cables |
11/30219798 DC : 0 | BS 7870-5 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 5: POLYMERIC INSULATED AERIAL BUNDLED CONDUCTORS (ABC) OF RATED VOLTAGE 0.6/1 KV FOR OVERHEAD DISTRIBUTION |
BS 7655-10.1(1997) : 1997 | SPECIFICATION FOR INSULATING AND SHEATHING MATERIALS FOR CABLES - POLYETHYLENE SHEATHING COMPOUNDS - THERMOPLASTIC MEDIUM DENSITY POLYETHYLENE (MDPE) SHEATHING COMPOUND |
BS 6500:2000 | Electric cables. Flexible cords rated up to 300/500 V, for use with appliances and equipment intended for domestic, office and similar environments |
BS 7655-0:1997 | Specification for insulating and sheathing materials for cables General introduction |
BS 7655-0:2006 | Specification for insulating and sheathing materials for cables General introduction |
BS 7870-5:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
BS 7870-8.2:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multipair cable with copper conductors - Section 8.2 Single wire armoured and PVC sheathed multipair cable with copper conductors |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 7870-8.6:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors |
BS 7919:2001 | Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment intended for industrial and similar environments |
EN 60811-1-3:1995/A1:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST |
ISO 18553:2002 | Method for the assessment of the degree of pigment or carbon black dispersion in polyolefin pipes, fittings and compounds |
IEC 60811-4-2:2004 | Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation |
IEC 60811-1-3:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test |
ISO 1133:2005 | Plastics Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.