BS EN 60662:2012+A11:2019
Current
The latest, up-to-date edition.
High-pressure sodium vapour lamps. Performance specifications
Hardcopy , PDF
English
01-03-2019
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General lamp requirements
5 Marking
6 Dimensions
7 Caps
8 Test requirements for lamp starting, warm-up, electrical
and photometric characteristics
9 Information for ballast and ignitor design
10 Information for luminaire design
11 Maximum lamp outlines
12 Numbering system for lamp data sheets
Annex A (normative) - Waveshape of voltage pulses for lamp
starting test (schematic drawings)
Annex B (informative) - Diagrammatic data sheets for location
of lamp dimensions
Annex C (normative) - Guidance for determining quadrilateral
diagrams
Annex D (normative) - Measurement of voltage increase at lamp
terminals for luminaire design
Annex E (informative) - HPS lamp drop-out voltage measurement
procedure
Annex F (normative) - Fixed settings of the ignition device
and requirements for ignition
Annex G (normative) - Method of measuring electrical and
photometrical characteristics
Annex H (normative) - Method of test for lumen maintenance
and life
Annex I (informative) - Maximum lamp outlines
Annex J (normative) - Lamp data sheets
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035.
Committee |
CPL/34/1
|
DevelopmentNote |
Supersedes BS 6193(1990) (05/2000) Supersedes 87/32546 DC, 92/33897 DC, 95/209182 DC, 91/03193 DC, and 96/209503 DC. (03/2006) Supersedes 09/30173981 DC. (05/2012)
|
DocumentType |
Standard
|
ISBN |
9780580514463
|
Pages |
196
|
ProductNote |
THE CONSOLIDATED VERSION IS AVAILABLE NOW THIS STANDARD ALSO REFERS TO EN 61347-2-1:2001/corrigendum Dec. 2010,, EN 61347-2-1:2001/corrigendum Jul. 2003,EN 60061-3:1969, CIE 13.3 1995, CIE 84:1989, CIE 015 2004, EN 61231, EN 60061-3:1969, EN 13032-1:2004, EN 60923:2005, EN 62321-4:2014, EN 61347-2-1:2001
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035.
For some of the requirements given in this standard, reference is made to “the relevant lamp data sheet”. For some lamps these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor.
The requirements of this standard relate only to type testing.
The requirements dealing with the lamp starting test and associated information for ballast/ignitor design are different depending on the practice of the country in which the lamp type was originally developed.
NOTE The requirements and tolerances permitted by this standard correspond to testing of a type test sample submitted by the manufacturer for that purpose. In principle, this type test sample should consist of units having characteristics typical of the manufacturer’s production and being as close to the production centre point values as possible.
It may be expected with the tolerances given in the standard that product manufactured in accordance with the type test sample will comply with the standard for the majority of production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see IEC 60410.
Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be used instead of the limits specified in this standard.
Standards | Relationship |
DIN EN 60662:2013-03 | Identical |
EN 60662:2012 | Identical |
EN 60662:2012/A11:2019 | Identical |
NF EN 60662 : 2013 | Identical |
NBN EN 60662 : 2012 | Identical |
UNE-EN 60662:1996 | Identical |
SN EN 60662 : 1993 AMD 10 1997 | Identical |
NEN EN 60662 : 1989 | Identical |
I.S. EN 60662:2012 | Identical |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC 60050-845:1987 | International Electrotechnical Vocabulary (IEV) - Part 845: Lighting |
EN 61347-2-1:2001/A2:2014 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) (IEC 61347-2-1:2000/A2:2013) |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters) |
EN 60923:2005/A1:2006 | AUXILIARIES FOR LAMPS - BALLASTS FOR DISCHARGE LAMPS (EXCLUDING TUBULAR FLUORESCENT LAMPS) - PERFORMANCE REQUIREMENTS |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 62035:2014+AMD1:2016 CSV | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
EN 62035:2014 | Discharge lamps (excluding fluorescent lamps) - Safety specifications |
IEC 61231:2010+AMD1:2013 CSV | International lamp coding system (ILCOS) |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 61126:1992 | Procedure for use in the preparation of maximum lamp outlines |
IEC 60923:2005+AMD1:2006 CSV | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.