BS EN 60534-8-3:2011

Current

Current

The latest, up-to-date edition.

Industrial-process control valves Noise considerations. Control valve aerodynamic noise prediction method

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2011

$618.22
Including GST where applicable

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Valves with standard trim
6 Valves with special trim design
7 Valves with higher outlet Mach numbers
8 Valves with experimentally determined acoustical
  efficiency factors
9 Combination of noise produced by a control valve with
  downstream installed two or more fixed area stages
Annex A (informative) - Calculation examples
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Defines a theoretical method to predict the external sound-pressure level generated in a control valve and within adjacent pipe expanders by the flow of compressible fluids.

Committee
GEL/65/2
DevelopmentNote
Supersedes 97/262149 DC. (05/2005) Supersedes 09/30201330 DC. (07/2011)
DocumentType
Standard
Pages
52
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC 60534-8-3:2010 establishes a theoretical method to predict the external sound-pressure level generated in a control valve and within adjacent pipe expanders by the flow of compressible fluids. This method considers only single-phase dry gases and vapours and is based on the perfect gas laws. It is assumed that the downstream piping is straight for a length of at least 2 m from the point where the noise measurement is made. The method is applicable to the following single-stage valves:
- globe (straight pattern and angle pattern),
- butterfly,
- rotary plug (eccentric, spherical),
- ball, and
- valves with cage trims.
Specifically excluded are the full bore ball valves where the product FpC exceeds 50 % of the rated flow coefficient. This third edition cancels and replaces the second edition published in 2000. This edition constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:
- predicting noise as a function of frequency;
- using laboratory data to determine the acoustical efficiency factor.

Standards Relationship
I.S. EN 60534-8-3:2011 Identical
NF EN 60534-8-3 : 2011 Identical
IEC 60534-8-3:2010 Identical
SN EN 60534-8-3 : 2000 Identical
EN 60534-8-3:2011 Identical
DIN EN 60534-8-3:2011-10 Identical
EN 61188-5-8:2008 Identical

EN 60534-1:2005 Industrial-process control valves - Part 1: Control valve terminology and general considerations
ISA 75.01.01 : 2007 INDUSTRIAL-PROCESS CONTROL VALVES - PART 2-1: FLOW CAPACITY - SIZING EQUATIONS FOR FLUID FLOW UNDER INSTALLED CONDITIONS
IEC 60534-8-1:2005 Industrial-process control valves - Part 8-1: Noise considerations - Laboratory measurement of noise generated by aerodynamic flow through control valves
IEC 60534-2-1:2011 Industrial-process control valves - Part 2-1: Flow capacity - Sizing equations for fluid flow under installed conditions
IEC 60534-1:2005 Industrial-process control valves - Part 1: Control valve terminology and general considerations

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.