BS EN 60317-13:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specifications for particular types of winding wires Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200
Hardcopy , PDF
15-08-2024
English
30-06-2010
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and general notes on methods of
test and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion (nominal conductor diameters
from 0,250 mm up to and including 2,500 mm)
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes the requirements of enamelled round copper winding wire of class 200 with a dual coating.
Committee |
W/-
|
DevelopmentNote |
Renumbers and supersedes BS 6811-3.3(1993). Supersedes BS 6811-3.3(1989). 1995 version incorporates amendment 8888 to BS 6811-3.3(1993). To be read in conjunction with BS EN 60317-0.1. (10/2005) Supersedes 09/30200517 DC. (06/2010)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This Part of IEC60317 specifies the requirements of enamelled round copper winding wire of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220°C.
The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved.
The range of a nominal conductor diameters covered by this standard is as follows:
Grade1: 0,050mm up to and including 2,000mm;
Grade2: 0,050mm up to and including 5,000mm.
The nominal conductor diameters are specified in Clause4 of IEC60317-0-1.
Standards | Relationship |
DIN EN 60317-13:2011-02 | Identical |
UNE-EN 60317-13:2010 | Identical |
EN 60317-13:2010 | Identical |
NF EN 60317-13 : 2012 | Identical |
NBN EN 60317-13 : 2010 | Identical |
SN EN 60317-13 : 1994 AMD 1 1997 | Identical |
IEC 60317-13:2010 | Identical |
I.S. EN 60317-13:2010 | Identical |
EN 60317-0-1:2014 | Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire |
IEC 60317-0-1:2013 | Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire |
EN 60851-4:2016 | Winding wires - Test methods - Part 4: Chemical properties |
IEC 60851-4:2016 | Winding wires - Test methods - Part 4: Chemical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.