BS EN 60255-121:2014
Current
The latest, up-to-date edition.
Measuring relays and protection equipment Functional requirements for distance protection
Hardcopy , PDF
English
31-07-2014
1 Scope
2 Normative references
3 Terms and definitions
4 Specification of the function
5 Performance specifications
6 Functional tests
7 Documentation requirements
Annex A (informative) - Impedance characteristics
Annex B (informative) - Informative guide for
the behaviour of timers in distance protection
zones for evolving faults
Annex C (normative) - Setting example
Annex D (normative) - Calculation of mean, median
and mode
Annex E (informative) - CT saturation and influence
on the performance of distance relays
Annex F (informative) - Informative guide for testing
distance relays based on CT requirements specification
Annex G (informative) - Informative guide for
dimensioning of CTs for distance protection
Annex H (normative) - Calculation of relay settings
based on generic point P expressed in terms of
voltage and current
Annex I (normative) - Ramping methods for testing the
basic characteristic accuracy
Annex J (normative) - Definition of fault inception angle
Annex K (normative) - Capacitive voltage instrument
transformer model
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines minimum requirements for functional and performance evaluation of distance protection function typically used in, but not limited to, line applications for effectively earthed, three-phase power systems.
Committee |
PEL/95
|
DevelopmentNote |
Supersedes 10/30215568 DC. (07/2014)
|
DocumentType |
Standard
|
Pages |
152
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60255-121:2014 specifies minimum requirements for functional and performance evaluation of distance protection function typically used in, but not limited to, line applications for effectively earthed, three-phase power systems. This standard also defines how to document and publish performance tests. This standard covers distance protection function whose operating characteristic can be defined on an impedance plane and includes specification of the protection function, measurement characteristics, phase selection, directionality, starting and time delay characteristics. The test methodologies for verifying performance characteristics and accuracy are included in this standard. The standard defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. It also includes the instrument transformer requirements for the protection function. The general requirements for measuring relays and protection equipment are defined in IEC 60255-1.
Standards | Relationship |
EN 60255-121:2014 | Identical |
IEC 60255-121:2014 | Identical |
IEC 61869-2:2012 | Instrument transformers - Part 2: Additional requirements for current transformers |
EN 61869-2 : 2012 | INSTRUMENT TRANSFORMERS - PART 2: ADDITIONAL REQUIREMENTS FOR CURRENT TRANSFORMERS |
EN 61869-5:2011 | Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers |
EN 60255-1:2010 | Measuring relays and protection equipment - Part 1: Common requirements |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
IEC 61869-5:2011 | Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.