BS EN 60214-1:2014
Current
The latest, up-to-date edition.
Tap-changers Performance requirements and test methods
Hardcopy , PDF
English
30-09-2014
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Requirements for on-load tap-changers
6 Requirements for motor-drive mechanisms for
on-load tap-changers
7 Requirements for de-energized tap-changers
8 Requirements for motor-drive mechanisms for
de-energized tap-changers
9 Nameplate
10 De-energized tap-changer warning label
11 Manufacturers operating instructions
Annex A (normative) - Supplementary information on
switching duty on main and transition contacts
relating to resistor type tap-changers
Annex B (normative) - Supplementary information on
switching duty relating to reactor type
tap-changers
Annex C (normative) - Method for determining the
equivalent temperature of the transition
resistor using power pulse current
Annex D (informative) - Simulated a.c. circuits for
service duty and breaking capacity tests
Annex E (informative) - Example of a synthetic
test circuit for service duty test of
vacuum type tap-changers
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to on-load tap-changers of both resistor and reactor types, deenergized tap-changers, and their motor-drive mechanisms.
Committee |
PEL/14
|
DevelopmentNote |
Supersedes 01/202455 DC. (07/2003) Supersedes 13/30265253 DC. (10/2014)
|
DocumentType |
Standard
|
Pages |
80
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC60214 applies to on-load tap-changers of both resistor and reactor types, de-energized tap-changers, and their motor-drive mechanisms. It applies mainly to tap-changers immersed in mineral insulating oil according to IEC60296 but may also be used for tap-changers with air or gas insulation or immersed in other insulating liquids insofar as conditions are applicable. It applies mainly to tap-changers with arcing contacts but may also be used for arcing-free on-load tap-changers (such as electronic switching) insofar as conditions are applicable. This part of IEC60214 applies to power and distribution transformers of all types and also to reactors. It does not apply to transformers and reactors mounted on railway rolling stock.
Standards | Relationship |
IEC 60214-1:2014 | Identical |
I.S. EN 60214-1:2014 | Identical |
EN 60214-1:2014 | Identical |
UNE-EN 60214-1:2015 | Identical |
NF EN 60214-1 : 2015 | Identical |
NBN EN 60214-1 : 2014 | Identical |
DIN EN 60214-1 : 2015 | Identical |
IEC 60076-15:2015 | Power transformers - Part 15: Gas-filled power transformers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60599:2015 | Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 60599:2016 | Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-21:2011 | Power transformers - Part 21: Standard requirements, terminology, and test code for step-voltage regulators |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60214-2:2004 | Tap-changers - Part 2: Application guide |