FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Grouping and classification of intrinsically safe
   apparatus and associated apparatus
5 Levels of protection and ignition compliance
   requirements of electrical apparatus
6 Apparatus construction
7 Components on which intrinsic safety depends
8 Infallible components, infallible assemblies of
   components and infallible connections on which
   intrinsic safety depends
9 Supplementary requirements for specific apparatus
10 Type verifications and type tests
11 Routine verifications and tests
12 Marking
13 Documentation
Annex A (normative) - Assessment of intrinsically safe
        circuits
Annex B (normative) - Spark test apparatus for
        intrinsically safe circuits
Annex C (informative) - Measurement of creepage distances,
        clearances and separation distances through
        casting compound and through solid insulation
Annex D (normative) - Encapsulation
Annex E (informative) - Transient energy test
Annex F (normative) - Alternative separation distances
        for assembled printed circuit boards and
        separation of components
Annex G (normative) - Fieldbus intrinsically safe concept
        (FISCO) - Apparatus requirements
Annex H (informative) - Ignition testing of semiconductor
        limiting power supply circuits
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZY (informative) - Significant changes between
         this European Standard and EN 60079-11:2007
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives
National Annex NA (Informative) - EXPLOSIVE ATMOSPHERES
                  - Part 11: Equipment protection by
                  intrinsic safety 'i'

Describes the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres.

Committee
EXL/31
DevelopmentNote
Supersedes BS EN 50020 & 03/313440 DC. (03/2007) Supersedes BS EN 61241-11. Partially supersedes BS EN 60079-27. Supersedes 08/30175787 DC. (01/2012)
DocumentType
Standard
Pages
158
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres. This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion in the surrounding explosive atmospheres. This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC60079-0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are evaluated for use in such an atmosphere by applying this standard. The requirements for intrinsically safe systems are provided in IEC60079-25. This standard supplements and modifies the general requirements of IEC60079-0, except as indicated in Table1. Where a requirement of this standard conflicts with a requirement of IEC60079-0, the requirements of this standard shall take precedence. If requirements in this standard are applicable to both intrinsically safe apparatus and associated apparatus the term “apparatus” is used throughout the standard. This standard is for electrical equipment only; therefore the term “equipment” used in the standard always means “electrical equipment”. If associated apparatus is placed in the explosive atmosphere, it shall be protected by an appropriate Type of Protection listed in IEC60079-0, and then the requirements of that method of protection together with the relevant parts of IEC60079-0 also apply to the associated apparatus. Table 1 Applicability of specific clauses of IEC60079-0 Clause or subclause of IEC60079-0 IEC60079-0 clause application to IEC60079-11 Intrinsically safe apparatus Associated apparatus Ed. 5.0 (2007) (informative) Ed. 6.0 (2011) (informative) Clause / Subclause title (normative) Group I and Group II Group III 1 1 Scope Applies Applies Applies 2 2 Normative references Applies Applies Applies 3 3 Terms and definitions Applies Applies Applies 4 4 Equipment grouping Applies Applies Applies 4.1 4.1 Group I Applies Excluded Applies 4.2 4.2 Group II Applies Excluded Applies 4.3 4.3 Group III Excluded Applies Applies 4.4 4.4 Equipment for a particular explosive atmosphere Applies Applies Applies 5.1 5.1 Environmental influences Applies Applies Applies 5.1.1 5.1.1 Ambient temperature Applies Applies Applies 5.1.2 5.1.2 External source of heating or cooling Applies Applies Applies 5.2 5.2 Service temperature Applies Applies Applies 5.3.1 5.3.1 Determination of maximum surface temperature Applies Applies Excluded 5.3.2.1 5.3.2.1 Group I electrical equipment Applies Excluded Excluded 5.3.2.2 5.3.2.2 Group II electrical equipment Applies Excluded Excluded 5.3.2.3 5.3.2.3 Group III electrical equipment Excluded Applies Excluded 5.3.3 5.3.3 Small component temperature for Group I or Group II electrical equipment Applies Excluded Excluded 6.1 6.1 General Applies Applies Applies 6.2 6.2 Mechanical strength of equipment Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 6.3 6.3 Opening times Excluded Excluded Excluded 6.4 6.4 Circulating currents in enclosures (e.g. of large electrical machines) Excluded Excluded Excluded 6.5 6.5 Gasket retention Excluded except when 6.1.2.3a)is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 6.6 6.6 Electromagnetic and ultrasonic radiating equipment Applies Applies Excluded 7.1.1 7.1.1 Applicability Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 7.1.2 7.1.2.1 Specification of materials Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 7.1.3 7.1.2.2 Plastic materials Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 7.1.4 7.1.2.3 Elastomers Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 7.2 7.2 Thermal endurance Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 7.3 7.3 Resistance to light Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 7.4 7.4 Electrostatic charges on external non-metallic materials Applies Applies Excluded NR 7.5 Accessible metal parts Applies Applies Excluded 7.5 NR Threaded holes Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 8.1 8.1 Material composition Applies Applies Excluded 8.1.1 8.2 Group I Applies Excluded Excluded 8.1.2 8.3 Group II Applies Excluded Excluded 8.1.3 8.4 Group III Excluded Applies Excluded 8.2 NR Threaded holes Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 9 9 Fasteners Excluded Excluded Excluded 10 10 Interlocking devices Excluded Excluded Excluded 11 11 Bushings Excluded Excluded Excluded 12 12 Materials used for cementing Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 13 13 Ex Components Applies Applies Applies 14 14 Connection facilities and termination compartments Excluded Excluded Excluded 15 15 Connection facilities for earthing or bonding conductors Excluded Excluded Excluded 16 16 Entries into enclosures Excluded except when 6.1.2.3a) is applied Excluded except when 6.1.3 a) is applied. Excluded except when 6.1.2.3a) is applied 17 17 Supplementary requirements for rotating machines Excluded Excluded Excluded 18 18 Supplementary requirements for switchgear Excluded Excluded Excluded 19 19 Supplementary requirements for fuses Excluded Excluded Excluded 20 20 Supplementary requirements for plugs, socket outlets and connectors Excluded Excluded Excluded

Standards Relationship
IEC 60079-11:2011/ISH1:2014 Identical
NBN EN 60079-11 : 2012 Identical
NF EN 60079-11 : 2012 Identical
I.S. EN 60079-11:2012 Identical
EN 60079-11:2012 Identical
DIN EN 60079-11 : 2012 Identical
UNE-EN 60079-11:2013 Identical
IEC 60079-11:2011 Identical

BS 8608:2014 Specification for radio telemetry systems for use with respiratory protective devices used by emergency first responders
BS 6164:2011 Code of practice for health and safety in tunnelling in the construction industry
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
11/30218915 DC : DRAFT JAN 2011 BS 6164 - CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY
14/30281804 DC : 0 BS 8608 - SPECIFICATION FOR RADIO TELEMETRY SYSTEMS FOR THE FIRE AND RESCUESERVICE
EEMUA 138 : 2010 DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS
EI Model code of safe practice Part 15:2015 MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS
BS 10999:2010 Specification for distress signal units for the fire and rescue service
09/30194709 DC : 0 BS 10999 - SPECIFICATION FOR DISTRESS SIGNAL UNITS FOR THE FIRE AND RESCUE SERVICE

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 61158-2:2014 Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition
IEC 60317-3:2004+AMD1:2010 CSV Specifications for particular types of winding wires - Part 3: Polyester enamelled round copper wire, class 155
EN 62013-1:2006 Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion
IEC 60317-7:1990+AMD1:1997+AMD2:1997 CSV Specifications for particular types of winding wires - Part 7: Polyimide enamelled round copper wire, class 220
EN 60085:2008 Electrical insulation - Thermal evaluation and designation
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
IPC 2152 : 0 STANDARD FOR DETERMINING CURRENT CARRYING CAPACITY IN PRINTED BOARD DESIGN
IEC 60317-8:2010 Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180
IEC 62013-1:2005 Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
EN 60317-13:2010 Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200
EN 60079-25:2010/AC:2013 EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010)
IEC 60317-13:2010 Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
EN 61158-2:2014 Industrial communication networks - Fieldbus specifications - Part 2: Physical layer specification and service definition
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
EN 60317-8:2010 Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180
HD 555.7 : 200S2 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - POLYIMIDE ENAMELLED ROUND COPPER WINDING WIRE, CLASS 220
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60664-3:2017 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 61086-1:2004 Coatings for loaded printed wire boards (conformal coatings) - Part 1: Definitions, classification and general requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.