BS EN 60076-14:2013
Current
The latest, up-to-date edition.
Power transformers Liquid-immersed power transformers using high-temperature insulation materials
Hardcopy , PDF
English
30-11-2013
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Insulation systems
5 Temperature rise limits
6 Components and materials
7 Special design considerations
8 Required information
9 Rating plate and additional information
10 Test requirements
11 Supervision, diagnostics, and maintenance
Annex A (informative) - Insulation materials
Annex B (informative) - Rapid temperature increase
and bubble generation
Annex C (informative) - Ester liquid and cellulose
Annex D (normative) - Insulation system coding
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to liquid-immersed power transformers employing either high-temperature insulation or combinations of high-temperature and conventional insulation, operating at temperatures above conventional limits.
Committee |
PEL/14
|
DevelopmentNote |
Supersedes DD IEC/TS 60076-14. Supersedes 12/30263868 DC. (11/2013)
|
DocumentType |
Standard
|
Pages |
62
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60076-14:2013 applies to liquid-immersed power transformers employing either high-temperature insulation or combinations of high-temperature and conventional insulation, operating at temperatures above conventional limits. It is applicable to:
- power transformers in accordance with IEC 60076-1;
- convertor transformers according to IEC 61378 series;
- transformers for wind turbine applications in accordance with IEC 60076-16;
- arc furnace transformers;
- reactors in accordance with IEC 60076-6. This part of IEC 60076 may be applicable as a reference for the use of high-temperature insulation materials in other types of transformers and reactors. This first edition of IEC 60076-14 cancels and replaces the second edition of the Technical Specification IEC/TS 60076-14 published in 2009. It constitutes a technical revision.
Standards | Relationship |
IEC 60076-14:2013 | Identical |
EN 60076-14:2013 | Identical |
ISO 2719:2016 | Determination of flash point — Pensky-Martens closed cup method |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEEE 62-1995 | IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors |
EN 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
IEC TS 62332-1:2011 | Electrical insulation systems (EIS) - Thermal evaluation of combined liquid and solid components - Part 1: General requirements |
IEC 61039:2008 | Classification of insulating liquids |
IEC 60422:2013 | Mineral insulating oils in electrical equipment - Supervision and maintenance guidance |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
IEC 60599:2015 | Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis |
EN 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
IEC 61100:1992 | Classification of insulating liquids according to fire-point and net calorific value |
IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
IEC 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60505:2011 | Evaluation and qualification of electrical insulation systems |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 61629-1:1996 | Aramid pressboard for electrical purposes - Part 1: Definitions, designations and general requirements |
IEC 60970:2007 | Insulating liquids - Methods for counting and sizing particles |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60944:1988 | Guide for the maintenance of silicone transformer liquids |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
IEC 60867:1993 | Insulating liquids - Specifications for unused liquids based on synthetic aromatic hydrocarbons |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 61378-3:2015 | Converter transformers - Part 3: Application guide |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbines applications |
IEC 61203:1992 | Synthetic organic esters for electrical purposes - Guide for maintenance of transformer esters in equipment |
IEEE C57.100-2011 | IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers |
IEEE 1276-1997 | IEEE Guide for the Application of High-Temperature Insulation Materials in Liquid-Immersed Power Transformers |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEEE C57.147-2008 | IEEE Guide for Acceptance and Maintenance of Natural Ester Fluids in Transformers |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 60076-16:2011 | Power transformers - Part 16: Transformers for wind turbine applications |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
EN 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEC 60851-4:2016 | Winding wires - Test methods - Part 4: Chemical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.