BS EN 54-27:2015

Current

Current

The latest, up-to-date edition.

Fire detection and fire alarms systems Duct smoke detectors

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-05-2015

$669.38
Including GST where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, abbreviated terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification
8 Marking, labelling and packaging
9 Data
Annex A (normative) - Aerosol tunnel arrangement
         for response measurements
Annex B (normative) - Test aerosol for response threshold
         value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Apparatus for dazzling test
Annex E (normative) - Fire test room and working volume
         arrangements for fire tests
Annex F (normative) - Smouldering (pyrolysis) wood fire
         (TF2D)
Annex G (normative) - Flaming plastics (polyurethane) fire
         (TF4D)
Annex H (normative) - Low temperature black smoke
         (decaline) liquid fire (TF8D)
Annex I (informative) - Information concerning the
         construction of the tunnel for fire tests
Annex J (informative) - Information concerning the
         construction of the measuring ionization chamber
Annex K (informative) - Information about DSD used as
         a stand-alone system
Annex L (informative) - Power supply
Annex M (informative) - Information concerning test
         procedures and requirements for the response to
         slowly developing fires
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Regulation
Bibliography

Defines requirements, test methods and performance criteria for fire detectors which detect smoke in air ducts in buildings as a part of a fire detection and fire alarm system or as an actuator for a fire protection system.

Committee
FSH/12/2
DevelopmentNote
Supersedes 08/30188489 DC. (05/2015)
DocumentType
Standard
Pages
86
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard specifies requirements, test methods and performance criteria for fire detectors which detect smoke in air ducts in buildings as a part of a fire detection and fire alarm system or as an actuator for a fire protection system. Duct smoke detectors with special characteristics and developed for specific risks are not covered by this document. NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from one member state to another and are not specified in this standard.

Standards Relationship
EN 54-27:2015 Identical

BS 9999:2017 Fire safety in the design, management and use of buildings. Code of practice

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60950-1:2006/A2:2013 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED)
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-13:2017 Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction