Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 54-10:2002

Current

Current

The latest, up-to-date edition.

Fire detection and fire alarm systems Flame detectors. Point detectors

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-09-2006

$618.22
Including GST where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
   4.1 Compliance
   4.2 Classification
   4.3 Individual alarm indication
   4.4 Connection of ancillary devices
   4.5 Monitoring of detachable detectors
   4.6 Manufacturer's adjustment
   4.7 On-site sensitivity adjustment
   4.8 Data
   4.9 Additional requirements for software controlled
        detectors
        4.9.1 General
        4.9.2 Software documentation
        4.9.3 Software design
        4.9.4 The storage of programs and data
5 Tests
   5.1 General
        5.1.1 Atmospheric conditions for tests
        5.1.2 Operating conditions for tests
        5.1.3 Mounting arrangements
        5.1.4 Tolerances
        5.1.5 Determination of response point
        5.1.6 Test procedure
        5.1.7 Reduced functional tests
        5.1.8 Provision for tests
        5.1.9 Test schedule
   5.2 Reproducibility
        5.2.1 Object
        5.2.2 Test procedure
        5.2.3 Requirements
   5.3 Repeatability
        5.3.1 Object
        5.3.2 Test procedure
        5.3.3 Requirements
   5.4 Directional dependence
        5.4.1 Object
        5.4.2 Test procedure
        5.4.3 Requirements
   5.5 Fire sensitivity
        5.5.1 Object
        5.5.2 Test procedure
        5.5.3 Classification
        5.5.4 Requirements
   5.6 Dazzling (operational)
        5.6.1 Object
        5.6.2 Test procedure and apparatus
        5.6.3 Requirements
   5.7 Dry heat (operational)
        5.7.1 Object
        5.7.2 Test procedure and apparatus
        5.7.3 Requirements
   5.8 Cold (operational)
        5.8.1 Object
        5.8.2 Test procedure and apparatus
        5.8.3 Requirements
   5.9 Damp heat, cyclic (operational)
        5.9.1 Object
        5.9.2 Test procedure and apparatus
        5.9.3 Requirements
   5.10 Damp heat, steady state (endurance)
        5.10.1 Object
        5.10.2 Test procedure and apparatus
        5.10.3 Requirements
   5.11 Sulfur dioxide (SO[2]) corrosion (endurance)
        5.11.1 Object
        5.11.2 Test procedure and apparatus
        5.11.3 Requirements
   5.12 Shock (operational)
        5.12.1 Object
        5.12.2 Test procedure and apparatus
        5.12.3 Requirements
   5.13 Impact (operational)
        5.13.1 Object
        5.13.2 Test procedure and apparatus
        5.13.3 Requirements
   5.14 Vibration, sinusoidal, (operational)
        5.14.1 Object
        5.14.2 Test procedure and apparatus
        5.14.3 Requirements
   5.15 Vibration, sinusoidal (endurance)
        5.15.1 Object
        5.15.2 Test procedure and apparatus
        5.15.3 Requirements
   5.16 Variation in supply parameters (operational)
        5.16.1 Object
        5.16.2 Test procedure
        5.16.3 Requirements
   5.17 Electromagnetic Compatibility (EMC), Immunity tests
        (operational)
        5.17.1 Object
        5.17.2 Test procedure and apparatus
        5.17.3 Requirements
6 Marking
Annex A (normative) Annex A Apparatus for response point
         determination
   A.1 Optical bench
   A.2 Radiation source
   A.3 Shutter
   A.4 Modulator
   A.5 Radiometer
Annex B (informative) Example of a methane burner
Annex C (normative) Test fires
   C.1 Methylated spirit fire
Annex D (normative) Apparatus for dazzling test
Annex E (normative) Apparatus for impact test
Annex ZA (informative) Clauses addressing the provisions of the EU
         Construction Products Directive 89/106/EEC
Bibliography

Covers requirements, test methods and performance criteria for point-type, resettable flame detectors that operate using radiation from a flame for use in fire detection systems installed in buildings.

Committee
FSH/12
DevelopmentNote
Supersedes 91/42154 DC. (03/2002) Supersedes 05/30133544 DC. (09/2007)
DocumentType
Standard
Pages
52
PublisherName
British Standards Institution
Status
Current
Supersedes

BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
01/540647 DC : DRAFT MAY 2001 BS 5839-1 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 1 - CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION AND MAINTENANCE
PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)

ISO 209-1:1989 Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-56:1988 Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more