BS EN 50525-2-51:2011

Current

Current

The latest, up-to-date edition.

Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-2011

$319.77
Including GST where applicable

1 Scope
2 Normative references
3 Terms and definitions
4 General purpose cables
Annex A (normative) - Tests for cables to EN 50525-2-51
Annex B (normative) - General data
Annex C (normative) - Dimensional calculations for cables
        with a non-preferred number of cores
Annex D (normative) - Requirements for compatibility test
National Annex (informative) - Origins and identification
               of the particular cable types
Bibliography

Pertains to oil resistant polyvinyl chloride insulated and sheathed flexible cables.

Committee
GEL/20/17
DevelopmentNote
Together with BS EN 50525-1, 2-11, 2-21, 2-83 & 3-21, supersedes BS 7919(2001). To be read in conjunction with BS EN 50525-1. Supersedes 08/30188804 DC. (10/2011)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard applies to oil resistant polyvinyl chloride insulated and sheathed flexible cables. Screened and non-screened types are included.

The cables are of rated voltages U0/U 300/500 V.

The cables are intended for the interconnection of manufacturing machines.

The maximum conductor operating temperature for the cables in this standard is 70 °C.

NOTE HD 516 contains extensive guidance on the safe use of cables in this standard.

This EN 50525-2-51 should be read in conjunction with EN 50525-1, which specifies general requirements.

Standards Relationship
IEC 60839-5-2:2016 Identical
EN 50525-2-51:2011 Identical

BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
12/30248753 DC : 0 BS 6004 - ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 460/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING
BS 6004:2012 Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

EN 60719:1993 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
IEC 60228:2004 Conductors of insulated cables
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
IEC 60719:1992 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
EN 50525-1:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
HD 308 S2:2001 Identification of cores in cables and flexible cords
IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 50363-3 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more