BS EN 50525-2-51:2011
Current
The latest, up-to-date edition.
Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation
Hardcopy , PDF
English
30-09-2011
1 Scope
2 Normative references
3 Terms and definitions
4 General purpose cables
Annex A (normative) - Tests for cables to EN 50525-2-51
Annex B (normative) - General data
Annex C (normative) - Dimensional calculations for cables
with a non-preferred number of cores
Annex D (normative) - Requirements for compatibility test
National Annex (informative) - Origins and identification
of the particular cable types
Bibliography
Pertains to oil resistant polyvinyl chloride insulated and sheathed flexible cables.
Committee |
GEL/20/17
|
DevelopmentNote |
Together with BS EN 50525-1, 2-11, 2-21, 2-83 & 3-21, supersedes BS 7919(2001). To be read in conjunction with BS EN 50525-1. Supersedes 08/30188804 DC. (10/2011)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard applies to oil resistant polyvinyl chloride insulated and sheathed flexible cables. Screened and non-screened types are included.
The cables are of rated voltages U0/U 300/500 V.
The cables are intended for the interconnection of manufacturing machines.
The maximum conductor operating temperature for the cables in this standard is 70 °C.
NOTE HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN 50525-2-51 should be read in conjunction with EN 50525-1, which specifies general requirements.
Standards | Relationship |
IEC 60839-5-2:2016 | Identical |
EN 50525-2-51:2011 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
12/30248753 DC : 0 | BS 6004 - ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 460/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING |
BS 6004:2012 | Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60719:1992 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
HD 308 S2:2001 | Identification of cores in cables and flexible cords |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
EN 50363-3 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS |
EN 50363-4-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds |
EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
EN 50334:2001 | Marking by inscription for the identification of cores of electric cables |
EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.