Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 50464-2-3:2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV Distribution transformers with cable boxes on the high-voltage and/or low-voltage side. Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1

Available format(s)

Hardcopy , PDF

Superseded date

26-03-2018

Superseded by

BS EN 50588-4:2018

Language(s)

English

Published date

31-08-2007

$268.61
Including GST where applicable

1 Scope
  1.1 High-voltage side
  1.2 Low-voltage side
2 Normative references
3 Definitions
4 High-voltage connections
5 Low-voltage connections
6 Design
7 Test

Describes cable boxes corresponding to cable boxes Type 2 in EN 50464-2-1 and are suitable for assembly on the cover of oil-immersed distribution transformers meeting the requirements of EN 50464-2-1.

Committee
PEL/14
DevelopmentNote
Supersedes BS 7821-2.3(1998). (08/2007)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Cable boxes described in this European Standard correspond to cable boxes Type 2 in EN 50464-2-1 and are suitable for assembly on the cover of oil-immersed distribution transformers meeting the requirements of EN 50464-2-1. Cable boxes are air-filled, metal- or non-metal enclosed, for high- and/or low-voltage connections in the following variations: 1.1 High-voltage side a) Connection directly to bushings; b) Connection via busbar system. 1.2 Low-voltage side a) Connection directly to bushings (maximum of four connectors per bushing); b) Connection via busbar system.

EN 50464-2-2:2007 Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1
EN 50386:2010/A1:2013 BUSHINGS UP TO 1 KV AND FROM 250 A TO 5 KA, FOR LIQUID FILLED TRANSFORMERS
EN 50180:2010 Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more