BS EN 50356:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Method for spark testing of cables

Available format(s)

Hardcopy , PDF

Superseded date

28-09-2007

Language(s)

English

Published date

23-07-2002

Introduction
1. Scope
2. Types of voltage waveform
3. Procedure
4. Equipment
5. Test voltage
6. Sensitivity
7. Calibration
Annex A (informative) Recommended minimum voltage levels
Annex B (informative) Example of an artificial fault device
Annex C (informative) Notes on the use of spark testing machines
Bibliography

Describes the operational requirements for the spark-test equipment, as well as the principal characteristics, functional parameters and calibration procedures for each type of test equipment.

Committee
GEL/20/17
DevelopmentNote
Supersedes 01/204786 DC (07/2002) Together with BS 5099(2004), it supersedes BS 5099(1992). (02/2004)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
DIN EN 50356 : 2003 Identical
NF EN 50356 : 2003 Identical
NBN EN 50356 : 2002 Identical
NEN EN 50356 : 2003 Identical
UNE-EN 50356:2003 Identical
SN EN 50356 : 2002 Identical
I.S. EN 50356:2002 Identical
EN 50356:2002 Identical

BS 8436:2004 Electric cables. 300/500 V screened electric cables having low emission of smoke and corrosive gases when affected by fire, for use in walls, partitions and building voids. Multicore cables
07/30143023 DC : DRAFT MAR 2007 BS 7835 - ELECTRIC CABLES - ARMOURED CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS
BS 7846:2015 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
12/30248753 DC : 0 BS 6004 - ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 460/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING
02/208358 DC : DRAFT SEP 2002 BS 7889/A2 - ELECTRIC CABLES - THERMOSETTING INSULATED, UNARMOURED CABLES FOR A VOLTAGE OF 600/1000 V
12/30248745 DC : 0 BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
06/30143016 DC : DRAFT SEP 2006 BS 6622 - SPECIFICATION FOR CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV
BS 6231:2006 Electric cables. Single core PVC insulated flexible cables of rated voltage 600/1000 V for switchgear and controlgear wiring
BS 6195:2006 Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads
BS 6622:2007 Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods
BS 7835:2007 Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods
BS 5099:2004 Electric cables. Voltage levels for spark testing
BS 6007:2006 Electric cables. Single core unsheathed heat resisting cables for voltages up to and including 450/750 V, for internal wiring
BS 7211:2012 Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire
02/210395 DC : DRAFT MAR 2003 ELECTRIC CABLES - VOLTAGE TEST LEVELS FOR SPARK TESTING
05/30138592 DC : DRAFT SEP 2005 BS 6231 - ELECTRIC CABLES - 600/1000 V, PVC INSULATED CABLES FOR SWITCHGEAR AND CONTROLGEAR WIRING
BS 6004:2012 Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting

IEC TS 60479-1:2005+AMD1:2016 CSV Effects of current on human beings and livestock - Part 1: Generalaspects

$319.77
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.