BS EN 50325-2:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by

Industrial communication subsystem based on ISO 11898 (CAN) for controller-device interfaces DeviceNet
Hardcopy , PDF
31-10-2009
English
15-07-2001
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Classification
4.1 General
4.2 DeviceNet communication model
4.3 DeviceNet and CAN
5 Characteristics
5.1 DeviceNet connections
5.2 DeviceNet messaging protocol
5.3 DeviceNet communication object classes
5.4 Network access state machine
5.5 Predefined master/slave connection set
5.6 Physical layer
6 Product information
6.1 Instructions for installation, operation and
maintenance
6.2 Marking
7 Normal service, transport and mounting conditions
7.1 Normal service conditions
7.2 Conditions during transport and storage
7.3 Mounting
8 Constructional and performance requirements
8.1 Indicators and configuration switches
8.2 DeviceNet cable
8.3 Terminating resistors
8.4 Connectors
8.5 Device taps and power taps
8.6 Network powered devices
8.7 Miswiring protection
8.8 Power supplies
8.9 Electromagnetic compatibility
9 Tests
9.1 General
9.2 Electrical and EMC testing
9.3 Logical testing
Annex A (normative) Common services
A.1 DeviceNet service codes and names
A.2 Common service definitions
Annex B (normative) DeviceNet error codes
Annex C (normative) Connection path attribute definition
C.1 General
C.2 Segment type format
C.3 Segment definition rules
Annex D (normative) Data type specification and encoding
D.1 Data type specification
D.2 Data type encoding
Annex E (normative) Communication objects library
E.1 General
E.2 Object Class Codes
E.3 Identity object (class code: 01 hex)
E.4 Message router object (class code: 02 hex)
E.5 DeviceNet object (class code: 03 hex)
E.6 DeviceNet connection object (class code: 05 hex)
E.7 Acknowledge handler object (class code: 2B hex)
Annex F (normative) Value ranges
Provides requirements for interfaces between controllers and switching elements, normal service conditions for devices, constructional and performance requirements and tests to verify conformance to requirements.
Committee |
GEL/65/3
|
DevelopmentNote |
Supersedes 98/617150 DC. (09/2005)
|
DocumentType |
Standard
|
Pages |
126
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 50325-2:2000 | Identical |
NF EN 50325-2 : 2001 | Identical |
NBN EN 50325-2 : 2001 | Identical |
DIN EN 50325-2:2001-06 | Identical |
NEN EN 50325-2 : 2000 | Identical |
SN EN 50325-2 : 2000 | Identical |
I.S. EN 50325-2:2001 | Identical |
ISO/IEC 7498-1:1994 | Information technology — Open Systems Interconnection — Basic Reference Model: The Basic Model |
IEC 61131-3:2013 | Programmable controllers - Part 3: Programming languages |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 61131-3:2013 | Programmable controllers - Part 3: Programming languages |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60947-5-2:2007/A1:2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-2: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - PROXIMITY SWITCHES (IEC 60947-5-2:2007/A1:2012) |
EN 50081-2:1993 | Electromagnetic compatibility - Generic emission standard - Part 2: Industrial environment |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61000-4-4:2012 | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 50082-2 : 95 AC 95 | ELECTROMAGNETIC COMPATIBILITY - GENERIC IMMUNITY STANDARD - INDUSTRIAL ENVIRONMENT |
IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.