BS EN 50299-1:2014
Current
The latest, up-to-date edition.
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Fluid-filled cable terminations
Hardcopy , PDF
English
31-01-2015
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Limits of supply
5 Rated values
6 Preferred values
7 Requirements
8 Tests
Bibliography
Includes the oil-immersed single-phase connection assembly of cables for transformers and reactors, designed in accordance with EN 60076 series.
Committee |
PEL/14
|
DevelopmentNote |
Together with BS EN 50299-2, it supersedes BS EN 50299 which remains current and will be withdrawn on 13/10/2017. Supersedes 13/30281713 DC. (02/2015)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard covers the oil-immersed single-phase connection assembly of cables for transformers and reactors, designed in accordance with EN60076 series. NOTE In the standard the term \'transformer\' is used as common definition for transformer and reactor. The purpose of EN50299‑1 is to establish for the cable assemblies: the electrical and mechanical requirements, including interchangeability; the limits of supply; the test to be carried out. It complements and amends, if necessary, the relevant IEC standards and applies to oil immersed cable connections, suitable for fluid-filled or dry-type cable terminations. EN50299‑1 does not cover direct cable terminations (see 3.1.1.3), but, in this case, upon agreement between purchaser and supplier, the standard may be used for guidance except for Figure1 and Figure2 which are not applicable. This standard applies to oil-immersed cable cable connection boxes on transformers with highest voltage for equipment U m=72,5kV to 550kV, including the current conductor terminal at the cable sealing end of the transformer.
Standards | Relationship |
EN 50299-1:2014 | Identical |
HD 632 : 1998 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
EN ISO 1302:2002 | Geometrical Product Specifications (GPS) - Indication of surface texture in technical product documentation (ISO 1302:2002) |
IEC 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.