BS EN 50265-2-1:1999

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame

Available format(s)

Hardcopy , PDF

Withdrawn date

27-10-2018

Language(s)

English

Published date

15-09-1999

$268.61
Including GST where applicable

1 Scope
2 Normative references
3 Definitions
4 Test apparatus
    4.1 General
    4.2 Ignition source
5 Procedure
    5.1 Sample
    5.2 Conditioning
    5.3 Positioning of test piece
    5.4 Flame application
6 Evaluation of test results
Annex A (informative) Recommended performance requirements
Annex B (informative) Bibliography

Specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure may not be suitable for small single insulated conductors or cables of less than 0.5 sq. mm. total cross-section, or for small optical fibre cables. In those cases, the procedure in BS EN 50265-2-2 is recommended.

Committee
GEL/20/18
DevelopmentNote
Supersedes 95/215049 DC. (03/2007)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
NF EN 50265-2-1 : 1999 Identical
NEN EN 50265-2-1 : 1999 Identical
I.S. EN 50265-2-1:1999 Identical
UNE-EN 50265-2-1:1999 Identical
SN EN 50265-2-1 : 1998 Identical
EN 50265-2-1:1998 Identical
DIN EN 50265-2-1 : 1999 Identical

BS 8436:2004 Electric cables. 300/500 V screened electric cables having low emission of smoke and corrosive gases when affected by fire, for use in walls, partitions and building voids. Multicore cables
BS 7870-6.3:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - Cables with thermosetting insulation and non-halogenated sheath
BS 7870-3.12:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
BS 7870-8.5:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath
BS 7870-3.21:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated split concentric cables with copper or aluminium conductors
BS 7846:2015 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
BS 7846:2000 Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire
DEFSTAN 07-247(PT1)/2(2006) : 2006 THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS
DEFSTAN 02-517(PT1)/2(2008) : 2008 REQUIREMENTS FOR CABLE, ELECTRIC - PART 1: PRESSURE-TIGHT ETHYLENE PROPYLENE RUBBER (EPR) OR SILICONE RUBBER INSULATED, CHLOROSULPHONATED POLYETHYLENE (CSP) LIMITED FIRE HAZARD (LFH) SHEATHED
DEFSTAN 07-247(PT1)/3(2009) : 2009 THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS
BS 7870-8.4:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance - Section 8.4 Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance
12/30248753 DC : 0 BS 6004 - ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 460/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING
02/208358 DC : DRAFT SEP 2002 BS 7889/A2 - ELECTRIC CABLES - THERMOSETTING INSULATED, UNARMOURED CABLES FOR A VOLTAGE OF 600/1000 V
BS 7629-2:1997 Specification for 300/500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire. Multipair cables
12/30248745 DC : 0 BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
02/208355 DC : DRAFT SEP 2002 BS 7629-1/A1 - 300/500 V FIRE RESISTANT ELECTRIC CABLES (HALOGEN-FREE) HAVING LOW EMISSION OF SMOKE WHEN AFFECTED BY FIRE - PART 1: MULTICORE CABLES
DEFSTAN 02-526/2(2008) : 2008 REQUIREMENTS FOR CABLES ELECTRIC, ELASTOMERIC, LIMITED FIRE HAZARD SHEATHED FOR GENERAL SERVICES
BS 6500:2000 Electric cables. Flexible cords rated up to 300/500 V, for use with appliances and equipment intended for domestic, office and similar environments
BS 6622:1999 Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV
BS 7835:2000 Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV having low emission of smoke and corrosive gases when affected by fire
BS 7870-3.11:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS 7211:2012 Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire
BS 7870-7.1:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring
BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors - Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors
BS 6346:1997 Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V
BS 7919:2001 Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment intended for industrial and similar environments
BS 7870-7.2:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring
BS 7870-6.1:1999 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations PVC insulated and PVC sheathed cables
02/208368 DC : DRAFT SEP 2002 BS 7211/A1 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES (HALOGEN-FREE) FOR VOLTAGES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE WHEN AFFECTED BY FIRE
BS 7870-3.20:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated split concentric cables with copper or aluminium conductors
02/208356 DC : DRAFT SEP 2002 BS 7629-2/A1 - 300/500 V FIRE RESISTANT ELECTRIC CABLES (HALOGEN-FREE) HAVING LOW EMISSION OF SMOKE WHEN AFFECTED BY FIRE - PART 2: MULTIPAIR CABLES
BS 7870-3.10:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS 6004:2012 Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting
BS 6004:2000 Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring

EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
EN 50265-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more