BS EN 50152-3-3:2016
Current
The latest, up-to-date edition.
Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Voltage transformers
Hardcopy , PDF
English
30-06-2016
European foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Service conditions
5 Rating
6 Design and construction
7 Tests
8 Rules for transport, storage, erection, operation
and maintenance
9 Safety
10 Influence of the product on the environment
11 Information to be given with enquiries, tenders
and orders
Bibliography
Pertains to new voltage transformers which are: - intended for use in indoor or outdoor fixed installations in tractions systems and - operated with an a.c. line voltage and frequency as specified in EN 50163.
Committee |
GEL/9/3
|
DevelopmentNote |
Supersedes 96/214119 DC. (09/2005) Supersedes 15/30314795 DC. (07/2016)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This EN50152-3-3 is applicable to new voltage transformers which are:
intended for use in indoor or outdoor fixed installations in tractions systems, and
operated with an a.c. line voltage and frequency as specified in EN50163.
NOTE1 EN50163 specifies the a.c. traction systems 15kV 16,7Hz and 25kV 50Hz.
NOTE2 As rails of a.c. traction systems are typically connected to earth and included in the return current path, all phase to earth voltages are subject to the limits as given in EN50163. Nevertheless conductor to conductor voltages are some times higher e.g. in autotransformer systems.
Voltage transformers are mainly used with:
measuring instruments,
protective devices.
This EN50152-3-3 also applies to voltage transformers other than inductive types as far as reasonably possible. Requirements of this EN50152-3-3 have priority.
NOTE3 Combined current and voltage transformers also capacitive voltage transformers are typically not used in fixed installations in traction systems.
Standards | Relationship |
I.S. EN 50152-3-3:2016 | Identical |
DIN EN 50152-3-3 : 2016 | Identical |
NEN EN 50152-3-3 : 2016 | Identical |
NF EN 50152-3-3 : 2017 | Identical |
UNE-EN 50152-3-3:2016 | Identical |
EN 50152-3-3:2016 | Identical |
SN EN 50152-3-3:2016 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
EN 50124-2:2017 | Railway applications - Insulation coordination - Part 2: Overvoltages and related protection |
IEC 61869-3:2011 | Instrument transformers - Part 3: Additional requirements for inductive voltage transformers |
EN 50122-1:2011/A4:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60050-605:1983 | International Electrotechnical Vocabulary (IEV) - Part 605: Generation, transmission and distribution of electricity - Substations |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC TR 61869-102:2014 | Instrument transformers - Part 102: Ferroresonance oscillations in substations with inductive voltage transformers |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 61869-3 : 2011 | INSTRUMENT TRANSFORMERS - PART 3: ADDITIONAL REQUIREMENTS FOR INDUCTIVE VOLTAGE TRANSFORMERS (IEC 61869-3:2011) |
IEC 61869-1:2007 | Instrument transformers - Part 1: General requirements |
EN 61869-1:2009 | Instrument transformers - Part 1: General requirements |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60050-446:1983 | International Electrotechnical Vocabulary (IEV) - Part 446: Electrical relays |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.