Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 416-2:2006

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Single burner gas-fired overhead radiant tube heaters for non-domestic use Rational use of energy

Available format(s)

Hardcopy , PDF

Superseded date

06-11-2019

Language(s)

English

Published date

30-06-2006

$588.37
Including GST where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification of appliances
  4.1 Classification according to the nature of the gases used
  4.2 Classification according to the gases capable of being used
  4.3 Classification according to the mode of evacuation of the
      combustion products
5 Symbols
6 Requirements for the rational use of energy
7 Test methods
  7.1 General
  7.2 Radiant factor
      7.2.1 General
      7.2.2 Method A
      7.2.3 Method B
Annex A (informative) Recording test data (Test Method A)
        A.1 General information to be recorded
        A.2 Measurement results
Annex B (informative) Blank forms (Test method A)
        B.1 Model test result form - Quarter sphere burner end and
            opposite end
        B.2 Model test result form - Quarter cylinder (Burner side
            and opposite side)
        B.3 Model test result form - Half sphere for appliances less
            than or equal to 1,3 m long
Annex C (informative) Worked example (Test method A)
        C.1 Radiant factor - Recorder data and calculation
        C.2 Radiant output - Recorded data and calculation
            C.2.1 Quarter spheres (Burner end and opposite end)
            C.2.2 Quarter cylinders (Burner side and opposite side)
Annex D (normative) Procedure for measuring the window correction
        factor (F[w]) (Test method A)
Annex E (normative) Correction of measured radiant output for
        absorption by air (Test methods A and B)
        E.1 General
        E.2 Mean beam length (D)
        E.3 Absorption of radiation by water vapour
        E.4 Absorption of radiation by carbon dioxide
        E.5 Total radiation absorption
        E.6 Calculation method
Annex F (informative) Radiant heat output data - Recording of
        results (Test method B)
        F.1 General information to be recorded
            F.1.1 Test and appliance data
            F.1.2 Radiometer technical data
            F.1.3 Measuring plane technical data
        F.2 Measurement results
            F.2.1 Test information
            F.2.2 Test ambient conditions
            F.2.3 Gas/heat input data
            F.2.4 Flue gas data
            F.2.5 Absorption of water vapour and CO[2] data
            F.2.6 Irradiation measurement data
Annex G (informative) Worked example (Test method B)
        G.1 General information
        G.2 Radiometer technical data
        G.3 Measuring plane technical data
        G.4 Measurement results
            G.4.1 Test information
            G.4.2 Test ambient conditions
            G.4.3 Gas/heat input data
            G.4.4 Flue gas data
            G.4.5 Absorption of water vapour and CO[2] data
            G.4.6 Irradiation measurement data
Annex H (informative) Radiometer design (Test method B)
        H.1 Principle radiometer design features
        H.2 Radiometer technical design
        H.3 Pyro-electric detector
Annex I (normative) Radiometer calibration (Test method B)
        I.1 Radiometer calibration
            I.1.1 General
            I.1.2 Black Body calibration method
        I.2 Worked example
Annex ZA (informative) Relationship between this European
         Standard and the Essential Requirements or other
         provisions of EU Directives

Describes the requirements and test methods for the rational use of energy of non-domestic gas fired overhead radiant tube heater.

Committee
GSE/20
DevelopmentNote
Together with BS EN 419-2, it supersedes DD ENV 1259-1, DD ENV 1259-2 and DD ENV 1259-3 Supersedes 01/712349 DC (06/2006)
DocumentType
Standard
Pages
48
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
UNI EN 416-2 : 2006 Identical
EN 416-2:2006 Identical
DIN EN 416-2:2006-10 Identical
NF EN 416-2 : 2006 Identical
NS EN 416-2 : 1ED 2006 Identical
NEN EN 416-2 : 2006 Identical
I.S. EN 416-2:2006 Identical
SN EN 416-2 : 2006 Identical
UNE-EN 416-2:2006 Identical
NBN EN 416-2 : 2006 Identical

AHRI 1330 : 2015 PERFORMANCE RATING FOR RADIANT OUTPUT OF GAS FIRED INFRARED HEATERS
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations

EN 416-1:2009 Single burner gas-fired overhead radiant tube heaters for non-domestic use - Part 1: Safety

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.