BS EN 40-3-1:2013
Current
The latest, up-to-date edition.
Lighting columns Design and verification. Specification for characteristic loads
Hardcopy , PDF
English
28-02-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Basis of loads
6 Forces and moments
Annex A (normative) - National wind and
meteorological information
Bibliography
Describes design loads for lighting columns. It also applies to lighting columns of nominal height (including any bracket) not exceeding 20 m.
Committee |
B/509/50
|
DevelopmentNote |
Supersedes BS 5649-6(1982) (05/2000) Supersedes 96/102122 DC. (09/2005) Supersedes 12/30260928 DC. (03/2013)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies design loads for lighting columns. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. Fibre reinforced polymer composite lighting columns are covered in this document, in conjunction with Annex B of EN 40-7:2002.
This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
Standards | Relationship |
UNE-EN 40-3-1:2013 | Identical |
UNI EN 40-3-1 : 2013 | Identical |
NS EN 40-3-1 : 2013 | Identical |
I.S. EN 40-3-1:2013 | Identical |
EN 40-3-1:2013 | Identical |
NF EN 40-3-1 : 2014 | Identical |
SN EN 40-3-1 : 2013 | Identical |
NEN EN 40-3-1 : 2013 | Identical |
DIN EN 40-3-1:2013-06 | Identical |
BS PD6547(2004) : 2004 | GUIDANCE ON THE USE OF BS EN 40-3-1 AND BS EN 40-3-3 |
BS PAS 68(2010) : 2010 | IMPACT TEST SPECIFICATIONS FOR VEHICLE SECURITY BARRIERS |
RSSB RIS-7702-INS : ISSUE 1 AMD 2 2014 | RAIL INDUSTRY STANDARD FOR LIGHTING AT STATIONS |
EN 40-1:1991 | Lighting columns - Part 1: Definitions and terms |
EN 12767:2007 | Passive safety of support structures for road equipment - Requirements, classification and test methods |
EN 40-7:2002 | Lighting columns - Part 7: Requirements for fibre reinforced polymer composite lighting columns |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.