BS EN 303-3:1999
Current
The latest, up-to-date edition.
Heating boilers Gas-fired central heating boilers. Assembly comprising a boiler body and a forced draught burner
Hardcopy , PDF
English
31-07-2006
Committee |
GSE/29
|
DevelopmentNote |
Supersedes 93/711568 DC. (09/2004)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies the requirements and test methods for the construction, the safety and the rational energy usage of an assembly made up of a boiler body complying with EN 303-11) and a forced draught gas burner complying with EN 676, using combustible gases, hereafter referred to as a “boiler??.
#This European Standard applies to standard boilers and low-temperature boilers with a nominal heat output not exceeding 1 000 kW and with a water temperature at normal operation not exceeding 105 °C.$
This European Standard does not contain all the necessary requirements for:
assemblies designed as units;
condensing boilers;
boilers intended to be installed in the open;
boilers permanently fitted with more than one flue outlet;
boilers fitted with a draught diverter;
boilers intended to be connected to a common flue having mechanical extraction.
This European Standard does not apply to living-space dedicated boilers (see 3.6).
If the boiler body has already been tested with a liquid fuel burner, in accordance with EN 303-1, EN 303-2 and EN 304, only the tests described in Annex G need to be performed.
In the case of a range of boilers, see Annex F.
Text deleted
This European Standard only covers type testing.
Standards | Relationship |
NBN EN 303-3 : 1999 COR 2006 | Identical |
NEN EN 303-3 : 1998 C1 2006 | Identical |
UNI EN 303-3 : 2007 | Identical |
NS EN 303-3 : 1998 AMD 2 2004 | Identical |
SN EN 303-3 : 1999 CORR 2006 | Identical |
DIN EN 303-3:2004-10 | Identical |
I.S. EN 303-3:1999 | Identical |
NF EN 303-3 : 1999 AMD 2 2004 | Identical |
UNE-EN 303-3:1999 | Identical |
DIN EN 303-3:1999-01 | Identical |
11/30229801 DC : 0 | BS 6644 - SPECIFICATION FOR THE INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
BS 6644(2005) : 2005 | SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
BS 6644:2011 | Specification for the installation and maintenance of gas-fired hot water boilers of rated inputs between 70 kW (net) and 1.8 MW (net) (2nd and 3rd family gases) |
03/310868 DC : DRAFT JUNE 2003 | BS 6644 - SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70KW (NET) AND 2MW (GROSS) (2ND AND 3RD FAMILY GASES) |
EN 304:2017 | Heating boilers - Test code for heating boilers for atomizing oil burners |
EN 303-1:2017 | Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking |
EN 303-2:2017 | Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners |