BS EN 14212:2012

Current

Current

The latest, up-to-date edition.

Ambient air. Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-05-2014

$669.38
Including GST where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Principle
6 Sampling
7 Analyser equipment
8 Type approval of ultraviolet fluorescence sulphur
   dioxide analysers
9 Field operation and ongoing quality control
10 Expression of results
11 Test reports and documentation
Annex A (normative) - Test of lack of fit
Annex B (informative) - Sampling equipment
Annex C (informative) - Ultraviolet fluorescence analyser
Annex D (informative) - Manifold testing
Annex E (normative) - Type approval
Annex F (informative) - Calculation of uncertainty in
        field operation at the hourly limit value
Annex G (informative) - Calculation of uncertainty in
        field operation at the daily limit value
Annex H (informative) - Calculation of uncertainty in
        field operation at the annual critical level
Annex I (informative) - Significant technical changes
Bibliography

Describes a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle.

Committee
EH/2/3
DevelopmentNote
Supersedes 01/562210 DC. (04/2005) Supersedes 10/30210750 DC. (09/2012)
DocumentType
Standard
Pages
108
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.

The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 μg/m3. This concentration range represents the certification range for SO2 for the type approval test.

NOTE 1 Other ranges may be used depending on the levels present in ambient air.

NOTE 2 When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.

The method covers the determination of ambient air concentrations of sulphur dioxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.

The results are expressed in μg/m3 (at 20 °C and 101,3 kPa).

NOTE 3 1 000 μg/m3 of SO2 corresponds to 376 nmol/mol of SO2.

This standard contains information for different groups of users.

Clauses 5 to 7 and Annexes C and D contain general information about the principles of sulphur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment.

Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of sulphur dioxide analysers. These sections contain information about:

  • Type-approval test conditions, test procedures and test requirements;

  • Analyser performance requirements;

  • Evaluation of the type-approval test results;

  • Evaluation of the uncertainty of the measurement results of the sulphur dioxide analyser based on the type-approval test results.

Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical measurements of sulphur dioxide in ambient air. These sections contain information about:

  • Initial installation of the analyser in the monitoring network and acceptance testing;

  • Ongoing quality assurance/quality control;

  • Calculation and reporting of measurement results;

  • Evaluation of the uncertainty of measurement results under practical monitoring conditions.

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 6144:2003 Gas analysis — Preparation of calibration gas mixtures — Static volumetric method
EN ISO 6142:2006 Gas analysis - Preparation of calibration gas mixtures - Gravimetric method (ISO 6142:2001)
ISO 6145-7:2009 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 7: Thermal mass-flow controllers
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN ISO 6145-7:2010 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 7: Thermal mass-flow controllers (ISO 6145-7:2009)
EN ISO 6143:2006 Gas analysis - Comparison methods for determining and checking the composition of calibration gas mixtures (ISO 6143:2001)
EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
EN ISO 6145-10:2008 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 10: Permeation method (ISO 6145-10:2002)
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN ISO 20988:2007 Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007)
ISO 6143:2001 Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ISO 6142:2001 Gas analysis Preparation of calibration gas mixtures Gravimetric method
ISO 6145-10:2002 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method
ISO 9001:2015 Quality management systems — Requirements
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN ISO 6145-6:2017 Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 6: Critical flow orifices (ISO 6145-6:2017)
ISO 20988:2007 Air quality Guidelines for estimating measurement uncertainty
ISO 6145-6:2017 Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
EN ISO 6144:2006 Gas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.