BS EN 13964:2014
Current
The latest, up-to-date edition.
Suspended ceilings. Requirements and test methods
Hardcopy , PDF
English
31-05-2014
Committee |
B/548
|
DevelopmentNote |
Supersedes BS 8290-1(1991), BS 8290-2(1991) & BS 8290-3(1991). (08/2004) Supersedes 01/101336 DC. (09/2004) Supersedes 13/30217369 DC. (03/2014)
|
DocumentType |
Standard
|
Pages |
134
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard covers membranes, individual substructure components, substructure kits and suspended ceiling kits intended to be placed on the market. It covers suspended ceilings sold as a complete kit, substructures placed on the market as kits, individual components (products) of such substructures, and membrane components. It includes test methods and methods of assessment, as well as provisions for the evaluation of conformity and for the marking of the products to the requirements of this European Standard.
In the absence of any other European Standard, this European Standard specifies dimensions, tolerances and, where relevant, performance requirements, for commonly available ceiling substructures and membrane components.
This European Standard covers the following characteristics:
reaction to fire;
fire resistance (suspended ceiling kits only);
release and/or content of dangerous substances:
release of asbestos (content) (suspended ceiling kits and membrane components only);
release of formaldehyde (suspended ceiling kits and membrane components only);
other dangerous substances;
shatter properties (safe breakage)/impact resistance (for suspended ceiling kits and membrane components of brittle materials in suspended ceiling kits only);
flexural tensile strength;
load bearing capacity, tolerances and dimensions;
electrical safety (as adequacy of the product to avoid electrocution from installations that may be part of the assembled ceiling, using electricity, such as ventilation devices and lighting);
direct airborne sound insulation (suspended ceiling kits only);
sound absorption (suspended ceiling kits and membrane components only);
thermal conductivity (suspended ceiling kits and membrane components only);
susceptibility to the growth of harmful micro-organisms;
resistance to fixings (relevant for components that are mechanically fixed);
durability of flexural tensile strength and load bearing capacity against moisture.
This European Standard also covers the following requirements:
colour and light reflectance;
installation.
This European Standard does not cover the following:
ceiling substructures and membrane component covered by other harmonized European Standards, for insitu formed ceilings, covered by other European technical specifications, for which it is the installer, not the component manufacturer, who takes responsibility for ensuring that the complete installed suspended ceiling meets any regulatory requirements to which it is subject;
stretched ceilings covered by EN 14716;
ceilings in mobile buildings, caravans and other forms of transportation;
characteristics needed for special applications, for which additional characteristics other than covered by this European Standard would need to be complied with;
suspended ceilings intended for uses in ceilings subject to water penetration requirements;
ceilings used externally where requirements other than covered by this standard would apply (tunnels, canopies, petrol stations, arcades, open sports facilities, car parks, etc.);
heavy duty suspended ceilings or their supporting construction (e.g. ceilings that can be walked on);
ceilings made from fire protective boards;
the performance and health and safety requirements of light fittings and other features that, optionally, are included in the suspended ceiling;
panels from materials covered in other harmonized European standards already prepared by CEN/TC 241 and CEN/TC 112 (see NOTE 1);
NOTE 1 These standards have been developed by CEN/TC 241 under the Mandate M/106 “Gypsum products” and by CEN/TC 112 under the Mandate M/113 “Wood-based panels”.
anchors covered by other European technical specifications.
This European Standard also gives certain specifications for the installed suspended ceiling system (see NOTE 2).
NOTE 2 There are two reasons for this:
the individual components and kits may have to meet certain requirements in order for the installed system to be able to meet the requirement when the system is installed, and
it is appropriate, for ease of reference, to give both component/kit requirement and installed system requirement in the same document, given the relationship between them.
This European Standard provides information for the various parties responsible for designing, manufacturing and specifying/selecting suspended ceilings used for interior applications in general building and civil engineering structures.
Standards | Relationship |
DIN EN 13964:2014-08 | Identical |
NF EN 13964 : 2014 | Identical |
UNE-EN 13964:2016 | Identical |
EN 13964:2014 | Identical |
NS EN 13964 : 2014 | Identical |
SN EN 13964 : 2014 | Identical |
NBN EN 13964 : 2014 | Identical |
UNI EN 13964 : 2014 | Identical |
I.S. EN 13964:2014 | Identical |
NEN EN 13964 : 2014 | Identical |
EN 520:2004+A1:2009 | Gypsum plasterboards - Definitions, requirements and test methods |
EN 13658-1:2005 | Metal lath and beads - Definitions, requirements and test methods - Part 1: Internal plastering |
EN 12667:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance |
ISO 10211:2017 | Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations |
EN 12602:2016 | Prefabricated reinforced components of autoclaved aerated concrete |
EN 120:1992 | Wood based panels - Determination of formaldehyde content - Extraction method called the perforator method |
ISO 10848-2:2017 | Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms — Part 2: Application to Type B elements when the junction has a small influence |
EN 13986:2004 | Wood-based panels for use in construction - Characteristics, evaluation of conformity and marking |
ISO 354:2003 | Acoustics — Measurement of sound absorption in a reverberation room |
EN 14190:2014 | Gypsum board products from reprocessing - Definitions, requirements and test methods |
EN 12354-6:2003 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 6: Sound absorption in enclosed spaces |
EN 10152:2017 | Electrolytically zinc coated cold rolled steel flat products for cold forming - Technical delivery conditions |
EN 335:2013 | Durability of wood and wood-based products - Use classes: definitions, application to solid wood and wood-based products |
EN 1520:2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
EN 10244-2:2009 | Steel wire and wire products - Non-ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings |
EN 13245-1:2010 | Plastics - Unplasticized poly(vinyl chloride) (PVC-U) profiles for building applications - Part 1: Designation of PVC-U profiles |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 717-1:2004 | Wood-based panels - Determination of formaldehyde release - Part 1: Formaldehyde emission by the chamber method |
ISO 7724-2:1984 | Paints and varnishes Colorimetry Part 2: Colour measurement |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
EN 1396:2015 | Aluminium and aluminium alloys - Coil coated sheet and strip for general applications - Specifications |
EN 10346:2015 | Continuously hot-dip coated steel flat products for cold forming - Technical delivery conditions |
EN 312:2010 | Particleboards - Specifications |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
ISO 11654:1997 | Acoustics — Sound absorbers for use in buildings — Rating of sound absorption |
EN ISO 6946:2017 | Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12) |
EN 15283-2:2008+A1:2009 | Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 2: Gypsum fibre boards |
EN 14566:2008+A1:2009 | Mechanical fasteners for gypsum plasterboard systems - Definitions, requirements and test methods |
EN 13162:2012+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
ISO 7724-3:1984 | Paints and varnishes Colorimetry Part 3: Calculation of colour differences |
EN 10169:2010+A1:2012 | Continuously organic coated (coil coated) steel flat products - Technical delivery conditions |
EN 15283-1:2008+A1:2009 | Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 1: Gypsum boards with mat reinforcement |
EN ISO 354:2003 | Acoustics - Measurement of sound absorption in a reverberation room (ISO 354:2003) |
EN 10143:2006 | Continuously hot-dip coated steel sheet and strip - Tolerances on dimensions and shape |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN ISO 10211:2017 | Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2017) |
EN 1168:2005+A3:2011 | Precast concrete products - Hollow core slabs |
EN 12664:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance |
EN 13171:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 12944-3:2017 | Paints and varnishes — Corrosion protection of steel structures by protective paint systems — Part 3: Design considerations |
EN 460:1994 | Durability of wood and wood-based products - Natural durability of solid wood - Guide to the durability requirements for wood to be used in hazard classes |
ISO 1006:1983 | Building construction Modular coordination Basic module |
ISO 717-1:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation |
ISO 6946:2017 | Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods |
EN ISO 11654:1997 | Acoustics - Sound absorbers for use in buildings - Rating of sound absorption (ISO 11654:1997) |
EN 622-1:2003 | Fibreboards - Specifications - Part 1: General requirements |
EN 573-3:2013 | Aluminium and aluminium alloys - Chemical composition and form of wrought products - Part 3: Chemical composition and form of products |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
ISO 2813:2014 | Paints and varnishes — Determination of gloss value at 20°, 60° and 85° |
EN 13963:2014 | Jointing materials for gypsum boards - Definitions, requirements and test methods |
EN ISO 2813:2014 | Paints and varnishes - Determination of gloss value at 20°, 60° and 85° (ISO 2813:2014) |
EN ISO 10848-2:2017 | Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 2: Application to Type B elements when the junction has a small influence (ISO 10848-2:2017) |
EN 14195:2014 | Metal framing components for gypsum board systems - Definitions, requirements and test methods |
EN 14716:2004 | Stretched ceilings - Requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.