BS EN 1364-1:2015
Current
The latest, up-to-date edition.
Fire resistance tests for non-loadbearing elements Walls
Hardcopy , PDF
English
31-07-2015
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (normative) - Specific requirements for testing
glazed elements or non-loadbearing walls
incorporating glazing
Annex B (normative) - Specific requirements for testing
non-loadbearing external and internal walls designed
to span horizontally between two independently
proven fire resisting vertical structural elements
Bibliography
Describes a method for determining the fire resistance of non-loadbearing walls.
Committee |
FSH/22/-/7
|
DevelopmentNote |
Supersedes 94/303844 DC. (09/2005) Supersedes 11/30252238 DC. (07/2015)
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European standard specifies a method for determining the fire resistance of non-loadbearing walls. This European Standard is used in conjunction with EN1363‑1 . It is applicable to internal non-loadbearing walls (partitions), with and without glazing, non-loadbearing walls consisting almost wholly of glazing (glazed non-loadbearing walls) and other non-loadbearing internal and external non-loadbearing walls with and without glazing. The fire resistance of external non-loadbearing walls can be determined under internal or external exposure conditions. In the latter case the external fire exposure curve given in EN1363‑2 is used. It is not applicable to: curtain walls (external non-loadbearing walls suspended in front of the floor slab), unless explicitly permitted under EN1364‑3 or EN1364‑4 which contain details of the methodology to be used. non-loadbearing walls containing door assemblies that are tested according to EN1634‑1 . Specific requirements for testing glazed elements or non-loadbearing walls incorporating glazing are given in AnnexA. Specific requirements relating to the testing of non-loadbearing external and internal walls designed to span horizontally between two independently proven fire resisting vertical structural elements are given in AnnexB.
Standards | Relationship |
EN 1364-1:2015 | Identical |
EN 1364-1:1999 | Identical |
I.S. EN 1364-1:2015 | Identical |
SN EN 1364-1 : 2015 | Identical |
NBN EN 1364-1 : 2015 | Identical |
UNE-EN 1364-1:2000 | Identical |
NEN EN 1364-1 : 2015 | Identical |
NS EN 1364-1 : 1999 | Identical |
UNI EN 1364-1 : 2002 | Identical |
NF EN 1364-1 : 2015 | Identical |
07/30147204 DC : 0 | BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS |
BS 5516-1:2004 | Patent glazing and sloping glazing for buildings Code of practice for design and installation of sloping and vertical patent glazing |
14/30295812 DC : 0 | BS 8458 - FIXED FIRE PROTECTION SYSTEMS - RESIDENTIAL AND DOMESTIC WATERMIST SYSTEMS - CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
09/30189801 DC : 0 | BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION |
PD 7974-3:2011 | Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin |
BS 476-10:2009 | Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs |
BS DD8458-1(2010) : 2010 | FIXED FIRE PROTECTION SYSTEMS - RESIDENTIAL AND DOMESTIC WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
PD 7974-3:2003 | Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin (Sub-system 3) |
BS 5516-2:2004 | Patent glazing and sloping glazing for buildings Code of practice for sloping glazing |
BS PAS 121(2007) : 2007 | SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING |
BS 8458:2015 | Fixed fire protection systems. Residential and domestic watermist systems. Code of practice for design and installation |
EN 1364-3:2014 | Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly) |
ISO 13943:2017 | Fire safety — Vocabulary |
EN 1364-4:2014 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.