BS EN 12543-4:1999
Current
The latest, up-to-date edition.
Non-destructive testing. Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing Edge method
Hardcopy , PDF
English
15-12-1999
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Measurement and determination of the focal spot size
Annex A (informative) Data analysis
Defines checking of focal spot dimensions higher than 0,5 mm of X-ray systems up to 500 kV tube voltage, by means of radiographs of sharp edges. Resolution and image quality of X-ray images are dependent on the features of the focal spot. Imaging qualities are based on two dimensional intensity distribution in the object plane. The edge procedure is particularly useful for focal spot checking under field conditions so as to find changes of the focal spot. It is unable to be used for complete measurement of the focal spot, for these measurements the method in accordance with annex A is applicable.
Committee |
WEE/46
|
DevelopmentNote |
Supersedes 96/715924 DC. (08/2005) Reviewed and confirmed by BSI, December 2008. (11/2008)
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNI EN 12543-4 : 2002 | Identical |
UNE-EN 12543-4:2000 | Identical |
EN 12543-4:1999 | Identical |
NEN EN 12543-4 : 1999 | Identical |
DIN EN 12543-4:1999-12 | Identical |
NS EN 12543-4 : 1ED 2000 | Identical |
NBN EN 12543-4 : 1999 | Identical |
I.S. EN 12543-4:2000 | Identical |
NF EN 12543-4 : 1999 | Identical |
SN EN 12543-4 : 1999 | Identical |
EN 25580:1992 | Non-destructive testing - Industrial radiographic illuminators - Minimum requirements (ISO 5580:1985) |
ISO 5580:1985 | Non-destructive testing — Industrial radiographic illuminators — Minimum requirements |
EN 584-1:2006 | Non-destructive testing - Industrial radiographic film - Part 1: Classification of film systems for industrial radiography |
EN 12543-1:1999 | Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 1: Scanning method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.