BS 8524-2:2013

Current

Current

The latest, up-to-date edition.

Active fire curtain barrier assemblies Code of practice for application, installation and maintenance

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2013

$618.22
Including GST where applicable

Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Specifying barrier assemblies
5 System design
6 Installation
7 Commissioning
8 Inspection, testing and maintenance
Annexes
Annex A (informative) - Typical approving authority
        pre-installation checklist
Annex B (informative) - An engineered approach to
        using radiative heat flux for tenable conditions
        for single-level horizontal routes
Annex C (informative) - Determining the fire resistance
        of barrier assemblies
Annex D (informative) - Typical installation checklist
Annex E (informative) - Model installation certificate
Annex F (informative) - Typical inspection checklist
Annex G (informative) - Model commissioning certificate
Annex H (informative) - Model completion certificate
Annex I (informative) - Model servicing certificate
Bibliography

Provides recommendations for the application, installation and maintenance of active fire curtain barrier assemblies.

Committee
FSH/25
DevelopmentNote
Supersedes 12/30205676 DC. (05/2013) Supersedes BS PAS 121(2007). (07/2013)
DocumentType
Standard
Pages
52
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of BS8524 gives recommendations for the application, installation and maintenance of active fire curtain barrier assemblies. It is applicable only to active fire curtain barrier assemblies conforming to BS8524‑1:2013 that are designed to provide fire resistance or fire and smoke resistance. NOTE Smoke barriers, used solely for smoke control, are covered by BSEN12101‑1. Such smoke barriers are not considered to be active fire curtain barrier assemblies within the scope of BS8524. This part of BS8524 is also intended to provide guidance and recommendations for designers, specifiers (e.g. architects, fire engineers), approving authorities, installers and maintainers for the following: creating compartmentation; creating protected routes for the purpose of means of escape; providing protection at the location of non-fire-resisting elements, e.g. in front of non-fire-resisting glazing and doorsets, where required for compartmentation or protecting means of escape; providing a fire- and smoke-resistant barrier in conjunction with non-smoke rated products protecting openings to reduce leakage of smoke.

BS 7346-8:2013 Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance
BS 9991:2015 Fire safety in the design, management and use of residential buildings. Code of practice
15/30301829 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
BS 8524-1:2013 Active fire curtain barrier assemblies Specification
16/30314117 DC : 0 BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE

BS PAS 121(2007) : 2007 SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING
BS EN 13501-2 : 2007 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
BS ISO 21927-9:2012 Smoke and heat control systems Specification for control equipment
BS EN 1634-1 : 2014 FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS
BS EN ISO 13943:2017 Fire safety. Vocabulary
BS EN 1634-3:2004 Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware Smoke control test for door and shutter assemblies
BS 8524-1:2013 Active fire curtain barrier assemblies Specification
BS EN 14600:2005 Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS EN 12259-5:2002 Fixed firefighting systems. Components for sprinkler and water spray systems Water flow detectors
PREN 16034 : DRAFT 2009 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS
BS 476-20:1987 Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles)
BS EN 1363-1:2012 Fire resistance tests General requirements
BS 8519:2010 Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice
BS EN 12101-1 : 2006 SMOKE AND HEAT CONTROL SYSTEMS - PART 1: SPECIFICATION FOR SMOKE BARRIERS
PD 7974-6:2004 The application of fire safety engineering principles to fire safety design of buildings Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6)
BS 5839-6:2004 Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings
BS 7974:2001 Application of fire safety engineering principles to the design of buildings. Code of practice
BS 476-31.1:1983 Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions
BS EN 12101-10:2005 Smoke and heat control systems Power supplies
BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more