BS 7846:2015
Current
The latest, up-to-date edition.
Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
Hardcopy , PDF
English
30-11-2015
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designation and fire resistance categories
5 Conductors
6 Insulation
7 Identification of cores
8 Laying-up
9 Bedding
10 Armour
11 Oversheath
12 Cable marking and additional information
13 End sealing
14 Schedule of tests
15 Test conditions
16 Routine tests
17 Sample tests
18 Type tests
Annexes
Annex A (informative) - Guide to use and installation of cables
Annex B (normative) - Armour wire tests
Annex C (normative) - Compatibility test
Annex D (normative) - Abrasion resistance test
Annex E (normative) - Insulation resistance constant
test on oversheath
Annex F (normative) - Resistance of armour
Annex G (informative) - Gross cross-sectional area of armour
Annex H (normative) - Test for shrinkage of oversheath
Annex I (normative) - Fire resistance test for category
F2 - Additional provisions for cables with a
diameter over 20 mm
Annex J (informative) - Guidance on type tests
Bibliography
Defines requirements for construction and performance of thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V having low emission of smoke and corrosive gases when affected by fire.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes 15/30301742 DC. (12/2015) Supersedes BS 7846(2009). (12/2016)
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies requirements for construction and performance of thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000V having low emission of smoke and corrosive gases when affected by fire. This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings or similar applications, where maintenance of power supply during a fire is required for a defined period of time. This British Standard specifies requirements for the following types of cables: wire armoured and oversheathed cables with two-, three-, four- or five-cores, and with stranded copper conductor; multicore auxiliary cables, wire armoured and oversheathed, with stranded copper conductor. This British Standard specifies four categories of cables based on their performance in tests which assess separately resistance to fire, resistance to fire with water spray and resistance to fire with mechanical shock (Category F2) and which assess resistance to fire with direct mechanical impact and water jet in combination (Categories F30, F60 and F120). This British Standard is applicable to cables that are designed for a maximum sustained conductor temperature of 90°C and for a maximum short-circuit conductor temperature of 250°C (for a maximum of 5s). NOTE1 Limitation on the temperature of the cables might be imposed in situations where they may be touched or where they could touch other materials. NOTE2 AnnexA gives the guide to use, AnnexB gives armour wire tests, AnnexC gives compatibility test, AnnexD gives abrasion test, AnnexE gives insulation resistance constant test on oversheath, AnnexF gives resistance of conductor and armour, AnnexG gives gross cross-sectional area of armour, AnnexH gives a test for shrinkage of oversheath, AnnexI gives the fire resistance test for category F2 – additional provisions for cables with a diameter over 20mm, and AnnexJ gives notes on type tests.
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
BS EN 62444:2013 | Cable glands for electrical installations |
BS EN 60811-401:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Thermal ageing methods. Ageing in an air oven |
BS EN 61034-2 : 2005 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS |
BS EN 60229:2008 | Electric cables. Tests on extruded oversheaths with a special protective function |
BS EN 60811-502:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations |
BS EN 61914:2016 | Cable cleats for electrical installations |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
BS 8491:2008 | Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems |
BS EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
BS EN 60332-3-24:2009 | Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C |
BS EN 10244-2:2009 | Steel wire and wire products. Non-ferrous metallic coatings on steel wire Zinc or zinc alloy coatings |
BS EN 62275:2015 | Cable management systems. Cable ties for electrical installations |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
BS EN 60811-501 : 2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 501: MECHANICAL TESTS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES OF INSULATING AND SHEATHING COMPOUNDS |
BS EN 50356:2002 | Method for spark testing of cables |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
BS EN 50395 : 2005 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS EN 62230 : 2007 | ELECTRIC CABLES - SPARK-TEST METHOD |
BS EN 50265-2-1:1999 | Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS EN 50363-5 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
BS EN 50266-2-4:2001 | Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. Procedures Category C |
BS EN 50396 : 2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS EN 60754-1:2014 | Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content |
BS 8512:2008 | Electric cables. Code of practice for the storage, handling, installation and disposal of cables on wooden drums |