BS 7629-1:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire Multicore and multipair cables

Available format(s)

Hardcopy , PDF

Superseded date

31-08-2015

Language(s)

English

Published date

30-11-2008

$443.41
Including GST where applicable

1. Foreword
2. Scope
3. Normative references
4. Terms and definitions
5. Voltage designation
6. Conductors and drain wire
7. Insulation
8. Identification of cores
9. Laying up
10. Screen
11. Sheath
12. Marking
13. Routine test for completed cables
14. Sample tests for completed cables
15. Type tests for completed cables
Annexes
Annex A (informative) - Recommendations for selection, operation
        and installation of cables
Annex B (informative) - Schedule of tests
Annex C (normative) - Measurement of insulation and sheath thickness
Annex D (normative) - Test conditions
Annex E (normative) - Method of test for insulation faults
Annex F (normative) - Method of test for voltage withstand
Annex G (normative) - Method of test for bending characteristics
Annex H (normative) - Method of test for resistance to impact
Bibliography

Defines requirements and test methods for the construction and performance of cables which: - have a thermosetting insulation of rated voltage 300/500 V; - provide resistance to fire (circuit integrity), including with mechanical shock and with water, as measured by performance in a standard test or tests; - emit limited amounts of smoke and corrosive gases as measured by standard tests; - are primarily intended for use in emergency lighting, fire detection and fire alarm system circuits.

Committee
GEL/20/17
DevelopmentNote
Supersedes BS 7629-1(1997), BS 7629-2(1997) and 08/30170023 DC. (11/2008)
DocumentType
Standard
Pages
0
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

DEFSTAN 02-357(PT4)/1(2010) : 2010 REQUIREMENTS FOR GASEOUS FIREFIGHTING SYSTEMS FOR MAIN AND AUXILIARY MACHINERY SPACES ON SURFACE SHIPS - PART 4: GENERAL REQUIREMENTS FOR INERT GAS SYSTEMS INCLUDING ELECTRIC/ELECTRONIC SPACES
BS 5839-8:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of voice alarm systems
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 9990:2015 Non automatic fire-fighting systems in buildings. Code of practice
BS 5266-1:2011 Emergency lighting Code of practice for the emergency escape lighting of premises
PD 6531:2010 Queries and interpretations on BS 5839-1

BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
BS EN 50267-2-2:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of degree of acidity of gases for materials by measuring pH and conductivity - Determination of degree of acidity of gases for materials by measuring pH and conductivity
BS EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
BS EN 61034-1 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS
BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
BS EN 60228:2005 Conductors of insulated cables
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS EN 13603:2013 Copper and copper alloys. Test methods for assessing protective tin coatings on drawn round copper wire for electrical purposes
BS EN 62230 : 2007 ELECTRIC CABLES - SPARK-TEST METHOD
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
BS EN 60684-2:2011 Flexible insulating sleeving Methods of test
BS EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds
BS EN 50363-5 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.