BS 7594:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Code of practice for audio-frequency induction-loop systems (AFILS)
Hardcopy , PDF
29-04-2020
English
30-09-2011
Foreword
Section 1: General
1 Scope
2 Normative references
3 Terms, definitions, signs and symbols
4 General
Section 2: Purchasing an AFILS, placing a contract
for its installation, or obtaining independent
assessment of the performance of an installation
5 Technical advice
6 Objective of the system
7 Choosing the system supplier
8 Contractual provisions
9 Factors to be considered at the design stage
Section 3: AFILS system design
10 Classification of systems
11 Signal sources
12 Objective measurement of intelligibility
13 Safety and reliability considerations
Section 4: Installing an AFILS
14 Responsibility of the installer
15 Installation practices and workmanship
16 Inspection and testing of wiring
17 Commissioning
18 Documentation
19 Certification
20 Acceptance
21 Verification
Section 5: Operation and maintenance
22 General
23 Routine testing
24 Inspection and servicing
25 Non-routine attention
Section 6: User responsibilities
26 Responsible person
27 Logbook
Section 7: System components
28 AFILS amplifiers
29 Loops
Annexes
Annex A (normative) - Induction-loop monitor
receivers
Annex B (informative) - What is an audio-frequency
induction-loop system (AFILS) and how does
it work?
Annex C (informative) - Explanations of the basis of
the design equations given in Section 3
Annex D (informative) - Model certificates
Annex E (informative) - Explanation of the specification
and measurement of magnetic field strength of
induction-loop systems
Annex F (normative) - Specification of the PPM-based
field strength meter
Annex G (informative) - Magnetic field direction near
the loop conductor
Bibliography
Provides recommendations for and guidance on the design, planning, installation, testing, operation and maintenance of an audio frequency induction loop system (AFILS) intended for communicating speech, music and/or other signals.
Committee |
EPL/100
|
DevelopmentNote |
Supersedes BS 7594(1993). (09/2011)
|
DocumentType |
Standard
|
Pages |
0
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This British Standard gives recommendations for and guidance on the design, planning, installation, testing, operation and maintenance of an audio frequency induction loop system (AFILS) intended for communicating speech, music and/or other signals. It is mainly concerned with AFILS for hearing enhancement, in which the signals are communicated to users of hearing aids equipped with magnetic pick-up coils. However, most of the standard also applies to AFILS used for other purposes, and some additional information on these purposes is given in Section3.
This standard does not apply to induction-loop systems which use a carrier frequency, nor to other systems for hearing enhancement purposes which do not use magnetic induction.
IEC 62489-1:2010+AMD1:2014 CSV | Electroacoustics - Audio-frequency induction loop systems for assisted hearing - Part 1: Methods of measuring and specifying theperformance of system components |
IEC 60268-10:1991 | Sound system equipment - Part 10: Peak programme level meters |
BS EN 61672-1:2013 | Electroacoustics. Sound level meters Specifications |
IEC 60118-1:1995+AMD1:1998 CSV | Hearing aids - Part 1: Hearing aids with induction pick-up coil input |
BS 6004:2000 | Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
DEFSTAN 61-12(PT6)/7(2009) : 2009 | WIRES, CORDS, AND CABLES, ELECTRICAL-METRIC UNITS - PART 6: CABLES, POLYVINYL CHLORIDE (PVC), POLYETHYLENE, OR SILICONE RUBBER INSULATED EQUIPMENT WIRES |
BS EN 60118-4:2006 | Electroacoustics. Hearing aids Induction loop systems for hearing aid purposes. Magnetic field strength |
BS EN 60268-16:2011 | Sound system equipment Objective rating of speech intelligibility by speech transmission index |
BS 6840-10:1991 | Sound system equipment Methods for specifying and measuring the characteristics of peak programme level meters |
IEC 60268-1:1985 | Sound system equipment. Part 1: General |
BS 6840-1:1987 | Sound system equipment Methods for specifying and measuring general characteristics used for equipment performance |
BS EN 50049-1:1998 | Domestic and similar electronic equipment interconnection requirements Peritelevision connector |
BS EN 62489-1 : 2010 | ELECTROACOUSTICS - AUDIO-FREQUENCY INDUCTION LOOP SYSTEMS FOR ASSISTED HEARING - PART 1: METHODS OF MEASURING AND SPECIFYING THE PERFORMANCE OF SYSTEM COMPONENTS |
BS EN 60065 : 2014 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014, MODIFIED) |
IEC 60118-4:2014+AMD1:2017 CSV | Electroacoustics - Hearing aids - Part 4: Induction-loop systems for hearing aid purposes - System performance requirements |
BS EN 60118-1:1995 | Hearing aids Hearing aids with induction pick-up coil input |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.