BS 5871-2:2005
Current
The latest, up-to-date edition.
Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases)
Hardcopy , PDF
English
30-11-2007
Committees responsible
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Exchange of information and planning
5 Appliances
6 Materials and components
7 Location
8 Appliance sizing
9 Ventilation
10 Flueing
11 Appliance fixing
12 Fire precautions
13 Gas supply
14 Electricity supplies and wiring
15 Ventilation (Fire/back boilers and fire/back
circulators only)
16 Appliance fixing (Fire/back boilers and fire/back
circulators only)
17 Fire precautions (Fire/back boilers and fire/back
circulators only)
18 Water connections (Fire/back boilers and fire/back
circulators only)
19 Commissioning
20 Instructions and use of fireguards
21 Advice to be given to the user
Annex A (informative) Calculation of required heat output
of a fire
Annex B (informative) Calculation of clearance flue flow
Bibliography
Describes installation and maintenance requirements for inset live fuel effect gas fires of heat input not exceeding 15 kW (16.6 kW based on gross calorific value) burning 2nd and 3rd family gases for the purpose of heating rooms or spaces in domestic or commercial premises.
Committee |
GSE/30/-/4
|
DevelopmentNote |
Supersedes 03/320605 DC & BS 5871-2(2001). (04/2005) Also available as part of BS KIT 174. (05/2005) Supersedes 07/301559372 DC. (01/2008)
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of BS 5871 specifies installation and maintenance requirements for inset live fuel effect gas fires of heat input not exceeding 15 kW (16.6 kW based on gross calorific value) burning 2nd and 3rd family gases for the purpose of heating rooms or spaces in domestic (see Note 5) or commercial premises. Combined appliances of the type where a fire is used in conjunction with a boiler or circulator are also covered in so far as the installation of the combined appliance is concerned. The standard is applicable to appliances intended for installation either: within a builder’s opening and/or fireplace recess and which may, additionally, be suitable for installation in a purpose designed metal flue box conforming to BS 715 and flue conforming to the constructional and temperature requirements of BS EN 1856-1 and BS EN 1856-2; or using a direct flue connection, if specified in the manufacturer’s instructions; or in the case of a room sealed appliance, using a flue terminal/air duct assembly supplied by the appliance manufacturer. This standard covers the selection of a suitable appliance, the ventilation and flueing requirements, and other measures necessary to ensure a safe installation. The central heating and/or hot water system connected to a combined appliance is not within the scope of this standard and reference should be made to BS 5449 (see Note 6) and BS 5546 for this part of such an installation. This standard is not applicable to mobile and portable appliances conforming to BS EN 449 or to appliances in touring caravans. Additional requirements for the installation of fire/back boilers and fire/back circulators are specified in Clauses 15, 16, 17 and 18. NOTE 1 Inset live fuel effect gas fires differ from decorative fuel effect gas appliances, which burn gas so as to simulate a solid fuel fire or produce other decorative effects, in that they incorporate a heat exchanger and restrict the passage of the products of combustion between the appliance firebed and the chimney or flue. The only decorative fuel effect gas appliances covered by this part of BS 5871 are those shown in Figure 1b) and detailed in 1d) of the commentary and recommendations on Clause 5 of this standard. NOTE 2 Unless the context requires otherwise, inset live fuel effect gas fires are hereinafter referred to as fires. NOTE 3 Heat inputs in this document are based on net calorific value. Figures based on gross calorific value are given in parenthesis where deemed necessary. See also Clause 5, commentary and recommendations g). NOTE 4 Attention is drawn to the foreword concerning the installation of used appliances. NOTE 5 As well as normally constructed dwellings, domestic premises include any permanently sited caravan holiday homes, residential park homes and permanently moored boats. See IGE/UP/8 [8]. NOTE 6 BS 5449 has been partly replaced by BS EN 12828 and BS EN 12831, and is to be withdrawn once BS EN 14336 and BS EN 14337 are published.
BS 5440-1:2008 | Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys |
BS 7967-2:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance |
BS 7977-1(2009) : 2009 | SPECIFICATION FOR SAFETY AND RATIONAL USE OF ENERGY OF DOMESTIC GAS APPLIANCES - PART 1: RADIANT/CONVECTORS |
BS 6798:2014 | Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net |
BS 8660-1:2011 | Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances |
BS 7967-3:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers |
BS 5440-2:2009 | Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for the installation and maintenance of ventilation provision for gas appliances |
BS 6798:2009 | Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net |
BS 5546:2010 | Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net |
BS 7967-1:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation |
BS 476-4:1970 | Fire tests on building materials and structures Non-combustibility test for materials |
BS 1289-1:1986 | Flue blocks and masonry terminals for gas appliances Specification for precast concrete flue blocks and terminals |
BS EN 1806:2006 | Chimneys Clay/ceramic flue blocks for single wall chimneys Requirements and test methods |
02/701494 DC : DRAFT FEB 2002 | HEATING SYSTEMS IN BUILDINGS - DESIGN AND INSTALLATION OF DIRECT ELECTRICAL ROOM HEATING SYSTEMS |
BS EN 13502:2002 | Chimneys. Requirements and test methods for clay/ceramic flue terminals |
BS 6700:1997 | Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages |
BS 7977-2:2003 | Specification for safety and rational use of energy of domestic gas appliances Combined appliances. Gas fire/back boiler |
BS 7435-2:1991 | Fibre cement flue pipes, fittings and terminals Specification for heavy quality fibre cement flue pipes, fittings and terminals |
02/701496 DC : DRAFT FEB 2002 | EN 14336 HEATING SYSTEMS IN BUILDINGS - INSTALLATION AND COMMISSIONING OF THE WHOLE SYSTEM |
BS EN 14336:2004 | Heating systems in buildings. Installation and commissioning of water based heating systems |
PD 6501-1:1982 | The preparation of British Standards for building and civil engineering Guide to the types of British Standard, their aims, relationship, content and application |
BS 6539:1984 | Specification for fireguards for use with solid fuel appliances |
BS 7977-1:2002 | Specification for safety and rational use of energy of domestic gas appliances Radiant/convectors |
BS EN 449 : 2002 | SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - DOMESTIC FLUELESS SPACE HEATERS (INCLUDING DIFFUSIVE CATALYTIC COMBUSTION HEATERS) |
BS 6461-1:1984 | Installation of chimneys and flues for domestic appliances burning solid fuel (including wood and peat) Code of practice for masonry chimneys and flue pipes |
BS EN 14337:2005 | Heating systems in buildings. Design and installation of direct electrical room heating systems |
BS 5482-2:1977 | Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings |
BS 7671(2001) : 2001 AMD 14905 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS 7860:1996 | Specification for carbon monoxide detectors (electrical) for domestic use |
BS 715:1993 | Specification for metal flue pipes, fittings, terminals and accessories for gas-fired appliances with a rated input not exceeding 60 kW |
BS EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
BS 5449:1990 | Specification for forced circulation hot water central heating systems for domestic premises |
BS EN 1443:2003 | Chimneys. General requirements |
CR 1472:1997 | General guidance for the marking of gas appliances |
BS EN 50291:2001 | Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements |
BS EN 1856-1:2009 | Chimneys. Requirements for metal chimneys System chimney products |
BS 6778:1986 | Specification for fireguards for use with portable, free-standing or wall-mounted heating appliances |
PD 6516:1987 | Guide to guarding fires and heating appliances |
BS EN 1856-2:2009 | Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes |
BS 7435-1:1991 | Fibre cement flue pipes, fittings and terminals Specification for light quality fibre cement flue pipes, fittings and terminals |