BS 5839-9:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
Hardcopy , PDF
26-08-2021
English
31-01-2011
Foreword
Introduction
Section 1: General
Section 2: Design considerations
Section 3: Installation
Section 4: Commissioning and handover
Section 5: Maintenance
Section 6: User responsibilities
Annexes
Annex A (informative) - Explanation of access
level
Annex B (normative) - Modified subclauses from
BS EN 54-2:1998
Annex C (informative) - Model certificates
Bibliography
Gives recommendations for the planning, design, installation, commissioning and maintenance of emergency voice communication systems in and around buildings and at sports, entertainment and similar venues. Narrates the use of emergency voice communication (EVC) in assisting both firefighters and those responsible for evacuating buildings or sports stadiums in fire emergency situations, including evacuation of disabled persons. Use, other than in fire emergency situations, by disabled persons and others, although not precluded, is not addressed in detail.
Committee |
FSH/12/5
|
DevelopmentNote |
Supersedes BS 5839-9(2003) & 09/30187281 DC. (02/2011)
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of BS5839 provides recommendations for the planning, design, installation, commissioning and maintenance of emergency voice communication systems in and around buildings and at sports, entertainment and similar venues. It does not recommend whether or not an emergency voice communication system should be installed in a given premises.
This part of BS5839 primarily relates to the use of emergency voice communication (EVC) in assisting both firefighters and those responsible for evacuating buildings or sports stadiums in fire emergency situations, including evacuation of disabled persons. Use, other than in fire emergency situations, by disabled persons and others, although not precluded, is not addressed in detail.
Other than in exceptional circumstances, EVC systems are not intended as the means of raising a fire alarm, in lieu of manual call points. Refer to BS5839‑1 for guidance on fire detection and alarm systems.
This part of BS5839 covers systems with components linked by wires, wirelessly, or a combination of both.
This part of BS5839 covers emergency voice communication systems and is therefore not intended to cover general-purpose intercom systems, lift intercom systems, local (internal) telephone systems for general use, or any external communication systems, such as the public switched telephone network and cellular telephone networks.
Voice alarm systems are primarily intended for the automatic broadcasting of evacuation messages; they are covered by BS5839‑8 and are therefore excluded from this part of BS5839.
BS 9999:2017 | Fire safety in the design, management and use of buildings. Code of practice |
BS 6259:2015 | Code of practice for the design, planning, installation, testing and maintenance of sound systems |
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
12/30260278 DC : 0 | BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
BS PAS 95(2011) : 2011 | HYPOXIC AIR FIRE PREVENTION SYSTEMS - SPECIFICATION |
16/30314117 DC : 0 | BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE |
BS EN 54-23:2010 | Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
BS EN 61672-1:2013 | Electroacoustics. Sound level meters Specifications |
BS 7594:1993 | Code of practice for audio-frequency induction-loop systems (AFILS) |
BS EN 54-16:2008 | Fire detection and fire alarm systems Voice alarm control and indicating equipment |
BS EN 60702-2 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS |
BS EN 54-4:1998 | Fire detection and fire alarm systems Power supply equipment |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 54-2 : 1998 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT |
BS EN 54-3:2014 | Fire detection and fire alarm systems Fire alarm devices. Sounders |
BS EN 60118-4:2006 | Electroacoustics. Hearing aids Induction loop systems for hearing aid purposes. Magnetic field strength |
BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
IEC 60702-2:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations |