BS 5588-10:1991
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
Hardcopy , PDF
06-10-2008
English
08-12-2004
Committees responsible
Foreword
Section 1. General
1 Scope
2 Definitions
3 Use of this code
Section 2. Analysis of the problem
4 Planning in relation to fire
5 Escape from fire
6 Uncovered shopping complexes, small shopping
developments and refurbishment of existing shopping
complexes
Section 3. Facilities for the fire service
7 Facilities for the fire service
Section 4. Planning of escape
8 General
9 Escape routes serving units and other occupancies
10 Escape routes serving other public facilities
11 Escape routes serving non-public common areas and
ancillary accommodation
12 Stairs and final exits
13 Wayfinding and spatial orientation (architectural
design, fire safety signs and messages)
Section 5. Construction
14 Construction
Section 6. Fire protection facilities
15 General
16 Fire detection and alarm systems
17 Control of evacuation in a fire
18 Automatic fire protection systems and special risk
protection
19 Manual firefighting equipment
20 Smoke control provisions
Section 7. Engineering services
21 General
22 Boiler rooms, fuel storage areas, transformer,
battery and switchgear rooms, and rooms housing
fixed internal combustion engines
23 Waste storage and treatment
24 Gas services
25 Electrical services
26 Lighting
27 Heating, mechanical ventilation and air conditioning
systems
28 Lifts and escalators
29 Incinerators
Section 8. Management
Appendix A Uncovered shopping complexes, small shopping
developments, refurbished and existing premises
incorporated into shopping complexes
Appendix B Impact resistance of partitions
Appendix C Commissioning and hand-over of smoke control systems
Publications referred to
Deals primarily with the common public and non-public areas of shopping complexes, although some recommendations affect the units forming the complex, particularly shop units.
Committee |
FSH/14
|
DevelopmentNote |
Supersedes 87/43818 DC. (07/2002) Reviewed and confirmed by BSI, January 2008. (12/2007)
|
DocumentType |
Standard
|
Pages |
102
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
BS 6229:2003 | Flat roofs with continuously supported coverings. Code of practice |
BS 5839-9:2003 | Fire detection and alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
BS 6259:1997 | Code of practice for the design, planning, installation, testing and maintenance of sound systems |
BS 5588-6:1991 | Fire precautions in the design, construction and use of buildings Code of practice for places of assembly |
BS 5839-8:1998 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning, and maintenance of voice alarm systems |
BS 5588-7:1997 | Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings |
BS 5499-4:2000 | Safety signs, including fire safety signs. Code of practice for escape route signing |
BS 5306-2:1990 | Fire extinguishing installations and equipment on premises Specification for sprinkler systems |
BS 5588-5:1991 | Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts |
BS 7346-4:2003 | Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice |
CEN/TR 12101-5:2005 | Smoke and heat control systems - Part 5: Guidelines on functional recommendations and calculation methods for smoke and heat exhaust ventilation systems |
BS 7083:1996 | Guide to the accommodation and operating environment for information technology (IT) equipment |
I.S. CEN/TR 12101-5:2005 | SMOKE AND HEAT CONTROL SYSTEMS - PART 5: GUIDELINES ON FUNCTIONAL RECOMMENDATIONS AND CALCULATION METHODS FOR SMOKE AND HEAT EXHAUST VENTILATION SYSTEMS |
BS 476-23:1987 | Fire tests on building materials and structures Methods for determination of the contribution of components to the fire resistance of a structure |
BS 476-4:1970 | Fire tests on building materials and structures Non-combustibility test for materials |
BS 5234-2:1992 | Partitions (including matching linings) Specification for performance requirements for strength and robustness including methods of test |
BS 5588-9:1989 | Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork |
BS 5588-2:1985 | Fire precautions in the design, construction and use of buildings Code of practice for shops |
BS 7346-2:1990 | Components for smoke and heat control systems Specification for powered smoke and heat exhaust ventilators |
BS 7346-3:1990 | Components for smoke and heat control systems Specification for smoke curtains |
BS 5906:1980 | Code of practice for storage and on-site treatment of solid waste from buildings |
BS 7036:1988 | Code of practice for provision and installation of safety devices for automatic power operated pedestrian door systems |
PD 6512-1:1985 | Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to fire doors |
BS 8214:1990 | Code of practice for fire door assemblies with non-metallic leaves |
BS 5655-6:2002 | Lifts and service lifts Code of practice for the selection and installation of new lifts |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
BS 5306-7:1988 | Fire extinguishing installations and equipment on premises Specification for powder systems |
PD 6520:1988 | Guide to fire test methods for building materials and elements of construction |
BS 5274:1985 | Specification for fire hose reels (water) for fixed installations |
BS 5306-0:1986 | Fire extinguishing installations and equipment on premises Guide for the selection of installed systems and other fire equipment |
BS 5395-3:1985 | Stairs, ladders and walkways Code of practice for the design of industrial type stairs, permanent ladders and walkways |
BS 5306-3:2000 | Fire extinguishing installations and equipment on premises Maintenance of portable fire extinguishers. Code of practice |
BS 476-11:1982 | Fire tests on building materials and structures Method for assessing the heat emission from building materials |
BS 476-6(1989) : 1989 | FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 6: METHOD OF TEST FOR FIRE PROPAGATION FOR PRODUCTS |
PD 6512-3:1987 | Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to the fire performance of glass |
BS 5588-6:1991 | Fire precautions in the design, construction and use of buildings Code of practice for places of assembly |
BS 476-20:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles) |
BS 5810:1979 | Code of practice for access for the disabled to buildings |
BS 476-21:1987 | Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction |
BS 5423:1987 | Specification for portable fire extinguishers |
BS 5725-1:1981 | Emergency exit devices Specification for panic bolts and panic latches mechanically operated by a horizontal push-bar |
BS 5306-1:1976 | Fire extinguishing installations and equipment on premises Hydrant systems, hose reels and foam inlets |
BS 5588-3:1983 | Fire precautions in the design, construction and use of buildings Code of practice for office buildings |
BS 5588-8:1988 | Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people |
BS 5839-3:1988 | Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment |
BS 5410-1:1997 | Code of practice for oil firing Installations up to 45 kW output capacity for space heating and hot water supply purposes |
BS 5410-2:1978 | Code of practice for oil firing Installations of 45 kW and above output capacity for space heating, hot water and steam supply services |
BS 5588-4:1978 | Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization |
BS 5395-2:1984 | Stairs, ladders and walkways Code of practice for the design of helical and spiral stairs |
BS 5720:1979 | Code of practice for mechanical ventilation and air conditioning in buildings |
BS 5588-1:1990 | Fire precautions in the design, construction and use of buildings Code of practice for residential buildings |
BS 476-31.1:1983 | Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions |
BS 476-8:1972 | Fire tests on building materials and structures Test methods and criteria for the fire resistance of elements of building construction |
BS 5306-3:2003 | Fire extinguishing installations and equipment on premises Code of practice for the inspection and maintenance of portable fire extinguishers |
BS 7346-1:1990 | Components for smoke and heat control systems Specification for natural smoke and heat exhaust ventilators |
BS 6262:1982 | Code of practice for glazing for buildings |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS 5588-7:1997 | Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.