BS 5546:2010
Current
The latest, up-to-date edition.
Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
Hardcopy , PDF
English
30-06-2010
Committee |
GSE/30
|
DevelopmentNote |
Supersedes BS 5546(2000) & 09/30166542 DC. (06/2010)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies requirements for the selection, installation, inspection, commissioning and maintenance of gas-fired water-heating appliances, which have a rated heat input not exceeding 70kW, based on net calorific value. It applies to water-heating appliances utilizing 1st, 2nd or 3rd family gases designed to operate in the condensing or non-condensing mode for the supply of hot water for domestic purposes in domestic dwellings or domestic dwellings in commercial premises. This standard does not apply to: water-heating appliances with a rated input of over 70kW; hot water supply systems in multiple dwellings supplied from a central source. NOTE1 Groups of water-heating appliances with individual ratings of less than 70kW but with a maximum aggregate input of 70kW may be installed to this Standard but specialist advice on the system design, installation and control needs to be sought from the appliance manufacturer. It does not cover the detailed design and installation of the whole hot water distribution system, which was specified in BS5449. NOTE2 With the publication of EN12828, EN12831 and EN14336, BS5449 has been withdrawn. These European standards, which have now been adopted as British Standards, are not aligned to UK design and installation practices; they cover commercial as well as domestic heating systems and exclude hot water. Consequently, they have been amended to include national annexes covering all the relevant material from BS5449. This standard applies to water-heating appliances which carry a CE mark and also to previously used water-heating appliances which do not carry the CE mark (see 5.3.1). NOTE3 In this standard, heat input is expressed in terms of net calorific values (CV), unless stated otherwise. The ratio of gross to net heat input is approximately 1.11:1 for natural gas, 1.09:1 for propane, and 1.08:1 for butane. NOTE4 It is essential that persons carrying out the installation of any gas appliance be competent to do so (see Clause4). NOTE5 Some parts of this standard might be appropriate for the installation of pool and spa water-heating appliances. The manufacturer’s instructions may advise which parts are not appropriate.
10/30213917 DC : 0 | BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES |
I.S. 327-3:1987 | DOMESTIC INSTALLATIONS USING LIQUEFIED PETROLEUM GASES |
13/30261683 DC : 0 | BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET |
BS 7967:2015 | Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fired appliances |
BS 6798:2014 | Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net |
I.S. 327-1:1987 | DOMESTIC INSTALLATIONS USING LIQUEFIED PETROLEUM GASES |
14/30258585 DC : 0 | BS 7967 - GUIDE FOR THE USE OF ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS FOR THE MEASUREMENT OF CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF DOMESTIC GAS FIRED APPLIANCES |
BS 8660-1:2011 | Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances |
BS 5864:2010 | Installation and maintenance of gas-fired ducted air heaters of rated heat input not exceeding 70 kW net (2nd and 3rd family gases). Specification |
BS 6340-2:1983 | Shower units Specification for the installation of shower units |
BS 476-4:1970 | Fire tests on building materials and structures Non-combustibility test for materials |
BS 5386-1:1976 | Specification for gas burning appliances Gas burning appliances for instantaneous production of hot water for domestic use |
BS 1566-2:1984 | Copper indirect cylinders for domestic purposes Specification for single feed indirect cylinders |
BS 1179-6:1980 | Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises |
BS 5258-8:1980 | Safety of domestic gas appliances Combined appliances: gas fire/back boiler |
BS 7927:1998 | Heating appliances for domestic applications. Portable apparatus designed to detect and measure specific combustion flue gas products. Requirements |
BS 5386-2:1981 | Specification for gas burning appliances Mini water heaters (2nd and 3rd family gases) |
BS 6700(2006) : 2006 | DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - SPECIFICATION |
BS EN 12897:2016 | Water supply. Specification for indirectly heated unvented (closed) storage water heaters |
BS EN 14336:2004 | Heating systems in buildings. Installation and commissioning of water based heating systems |
BS EN 1490:2000 | Building valves. Combined temperature and pressure relief valves. Tests and requirements |
BS 7967-2:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance |
BS 6400-2:2006 | Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Medium pressure (2nd family gases) |
PD 5482-3:2005 | Code of practice for domestic butane and propane gas-burning installations Installations in boats, yachts and other vessels |
BS 1212-2:1990 | Float operated valves Specification for diaphragm type float operated valves (copper alloy body) (excluding floats) |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6400-3:2007 | Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Low and medium pressure (3rd family gases) |
BS 5258-7:1977 | Safety of domestic gas appliances Storage water heaters |
BS 1566-1(2002) : 2002 | COPPER INDIRECT CYLINDERS FOR DOMESTIC PURPOSES - PART 1: OPEN VENTED COPPER CYLINDERS - REQUIREMENTS AND TEST METHODS |
BS 5482-2:1977 | Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings |
BS 3198:1981 | Specification for copper hot water storage combination units for domestic purposes |
BS 5386-5:1988 | Specification for gas burning appliances Specification for gas burning instantaneous water heaters with automatic output variation (2nd and 3rd family gases) |
BS 5258-15:1990 | Safety of domestic gas appliances Specification for combination boilers |
BS 3632:2005 | Residential park homes. Specification |
BS EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
BS 5449:1990 | Specification for forced circulation hot water central heating systems for domestic premises |
BS EN 1443:2003 | Chimneys. General requirements |
CR 1472:1997 | General guidance for the marking of gas appliances |
BS 7967-3:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers |
BS EN 50291:2001 | Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements |
BS EN 1856-1:2009 | Chimneys. Requirements for metal chimneys System chimney products |
BS 8525-1:2010 | Greywater systems Code of practice |
BS EN 12828 : 2012 | HEATING SYSTEMS IN BUILDINGS - DESIGN FOR WATER-BASED HEATING SYSTEMS |
BS 1179:1967 | Glossary of terms used in the gas industry |
BS 7967-1:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation |
BS EN 12831:2003 | Heating systems in buildings. Method for calculation of the design heat load |
BS 5422:2009 | Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C |
BS 1010-2:1973 | Specification for draw-off taps and stopvalves for water services (screw-down pattern) Draw-off taps and above-ground stopvalves |
PD CEN/TR 1749:2014 | European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types) |
BS 5871-2:2005 | Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases) |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS 7967-4:2007 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances |