Foreword
Committees responsible
Guide
Section one. General
1 Scope
2 Definitions
3 Range of information
Section two. Value of installed fire extinguishing
                systems
4 Historical development
5 Relation to other means of fire protection
Section three. Extinguishing media
6 General
7 Water
8 Gaseous extinguishing media
9 Foams
10 Powders
Section four. Effects of extinguishing media on people
                and materials
11 General
12 Water
13 Gaseous extinguishing media
14 Foams
15 Powders
Section five. Fixed systems and other fire
                extinguishing equipment
16 General
17 Hydrant systems, hose reels (water) and foam inlets
18 Automatic water systems
19 Portable fire extinguishers
20 Carbon dioxide systems
21 Halon systems
22 Foam systems
23 Powder systems
Section six. Dual use of media and systems
24 General
25 Examples of dual use of media and systems
Section seven. Control of fixed fire extinguishing
                systems
26 General
27 Water systems
28 Gaseous systems
29 Foam systems
30 Powder systems
Section eight. Characteristics of risks
31 General
32 Analysis
33 Information and advice
34 Questionnaire
Section nine. Selecting the system to suit the risk
35 General
36 Effect of system discharge on neighbouring
    occupancies
37 Effect of changing occupancies
Section ten. Installation, inspection and testing of
                systems and equipment
38 General
39 Installation
40 Acceptance testing
Section eleven. Servicing and maintenance of systems
41 General
42 Hydrant systems, hose reels and foam inlets
43 Sprinkler and water spray systems
44 Carbon dioxide systems
45 Halon systems
46 Foam systems
47 Extinguishing powder systems
Section twelve. Responsibility for fire extinguishing
                equipment and systems on premises
48 Contract arrangements
Appendices
A Typical applications of fire extinguishing systems
B Bibliography
Tables
1 Classes of sprinkler system for different hazard
    classifications
2 Typical applications for gaseous systems
Figures
1 Hydrant system hose reel and foam inlet installed in
    building
2 Automatic sprinkler system
3 Water spray system for limited area of risk
4 Carbon dioxide total flooding system protecting a
    turbo-generator with initial and delayed discharge
    over the whole volume
5 Carbon dioxide local application system protecting
    quench tank
6 Halon piped total flooding system protecting oil-
    filled switchgear and transformers using heat-
    operated pneumatic detectors
7 Halon modular total flooding system protecting
    electronic data processing equipment and tape
    storage rooms, using smoke detection
8 Pre-mixed foam system protecting a specific hazard
9 Low expansion foam deluge system using open foam
    nozzles or aspirating foam sprinklers
10 High expansion foam system for total flooding of a
    warehouse or storage
11 Extinguishing powder system protecting a cooking
    range

Describes and compares the characteristics of extinguishing media, systems and equipment, the performance and possible hazards of use, and the most suitable applications.

Committee
FSH/18
DevelopmentNote
Supersedes 84/38691 DC. (12/2002)
DocumentType
Standard
Pages
52
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS 5588-12:2004 Fire precautions in the design, construction and use of buildings Managing fire safety
BS 5588-1:1990 Fire precautions in the design, construction and use of buildings Code of practice for residential buildings
BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
BS 5306-6.2:1989 Fire extinguishing installations and equipment on premises. Foam systems Specification for medium and high expansion foam systems
BS 5588-10:1991 Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
BS 5306-3:1985 Fire extinguishing installations and equipment on premises Code of practice for selection, installation and maintenance of portable fire extinguishers
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 5588-6:1991 Fire precautions in the design, construction and use of buildings Code of practice for places of assembly
BS 5502-23:1990 Buildings and structures for agriculture Code of practice for fire precautions
BS 5306-6.1:1988 Fire extinguishing installations and equipment on premises. Foam systems Specification for low expansion foam systems
BS 5502-81:1989 Buildings and structures for agriculture Code of practice for design and construction of chemical stores
04/30104952 DC : DRAFT MARCH 2004 BS 5502-23 - BUILDING AND STRUCTURES FOR AGRICULTURE - PART 23 - FIRE PRECAUTIONS - CODE OF PRACTICE
BS 5502-23:2004 Buildings and structures for agriculture Fire precautions. Code of practice
BS 5306-2:1990 Fire extinguishing installations and equipment on premises Specification for sprinkler systems
BS 5306-5.1:1992 Code of practice for fire extinguishing installations and equipment on premises. Halon systems Specification for halon 1301 total flooding systems
BS 6266:2002 Code of practice for fire protection for electronic equipment installations
BS 5908:1990 Code of practice for fire precautions in the chemical and allied industries
BS 5306-1:2006 Code of practice for fire extinguishing installations and equipment on premises Hose reels and foam inlets
BS 8313:1997 Code of practice for accommodation of building services in ducts
BS 1133-4:1991 Packaging code Mechanical aids in package handling
BS 7083:1996 Guide to the accommodation and operating environment for information technology (IT) equipment
BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
BS 7083:1989 Recommendations for the accommodation and operating environment of computer equipment
BS 6164:1990 Code of practice for safety in tunnelling in the construction industry
BS 6164:2001 Code of practice for safety in tunnelling in the construction industry

BS 5306-5.2:1984 Code of practice for fire extinguishing installations and equipment on premises. Halon systems Halon 1211 total flooding systems
BS 5306-5.1(1982) : 1982 FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - HALON SYSTEMS - HALON 1301 TOTAL FLOODING SYSTEMS
BS 5423:1987 Specification for portable fire extinguishers
BS 5306-1:1976 Fire extinguishing installations and equipment on premises Hydrant systems, hose reels and foam inlets
BS 4422:2005 Fire. Vocabulary
BS 5306-2:1979 Fire extinguishing installations and equipment on premises Sprinkler systems
BS 5306-3:1985 Fire extinguishing installations and equipment on premises Code of practice for selection, installation and maintenance of portable fire extinguishers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more