BS 1363-1(1995) : 1995
Current
The latest, up-to-date edition.
13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 1: SPECIFICATION FOR REWIRABLE AND NON-REWIRABLE 13 A FUSED PLUGS
Hardcopy , PDF
English
01-01-1995
Committees responsible
Foreword
1 Scope
2 Conditions of use
3 Terms and definitions
4 General
5 General conditions for type testing
6 Classification
7 Marking and labelling
8 Clearances, creepage distances and solid insulation
9 Accessibility of live parts
10 Provision for earthing
11 Terminals and terminations
12 Construction of plugs
13 (Not used)
14 Resistance to ageing and to humidity
15 Insulation resistance and electric strength
16 Temperature rise
17 Breaking capacity of switches incorporated in fused plugs
18 Normal operation of switches
19 Connection of flexible cords and cord anchorage
20 Mechanical strength
21 Screws, current-carrying parts and connections
22 Resistance to heat
23 Resistance to abnormal heat, fire and tracking
24 Resistance to excessive residual stresses and to rusting
25 Electrical and thermal stress on clamp type (screwless)
terminals
26 Overload tests
Annex A (normative) - The construction and calibration of a
calibrated link
Annex B (normative) - Measurement of clearances and creepage
distances
Annex C (normative) - Determination of the Comparative Tracking
Index (CTI) and Proof Tracking Index (PTI)
Annex D (normative) - Relation between rated impulse withstand
voltage, rated voltage and Overvoltage Category
Annex E (normative) - Pollution degree
Annex F (normative) - Impulse voltage test
Annex G (informative) - Specific structure of BS EN 50525
and its derivation from British Standard and from
HD 21 and HD 22
List of references
Defines requirements for 13 A fused plugs having insulating sleeves on line and neutral pins, for household, commercial and light industrial purposes, with particular reference to safety in normal use.
Committee |
PEL/23
|
DevelopmentNote |
Together with BS 1363-2(1995), it supersedes BS 1363(1984) Supersedes 88/30090 DC, 96/208291 DC and 02/203986 DC (10/2003) Supersedes 06/30156710 DC. (01/2008) 1995 version along with its amendments remain current & will be withdrawn on 31/05/2015. 1995 Edition Re-Issued in May 2012 & incorporates AMD 4 2012. Supersedes 11/30203492 DC. (05/2012)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
TS 102 874-5 : 1.2.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); EXTERNAL COMMON POWER SUPPLY FOR CUSTOMER PREMISES NETWORK AND ACCESS EQUIPMENT; PART 5: CPS TYPE 2.C IMPLEMENTATION DETAILS |
CSA C22.2 No. 62368-1 : 2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
BS 6173:2009 | Specification for installation and maintenance of gas-fired catering appliances for use in all types of catering establishments (2nd and 3rd family gases) |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 62606:2013/A1:2017 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES (IEC 62606:2013/A1:2017) |
DEFSTAN 08-107/3(2013) : 2013 | GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROTECHNICAL AND NAVAL WEAPON EQUIPMENT |
TS 102 874-3 : 1.2.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); EXTERNAL COMMON POWER SUPPLY FOR CUSTOMER PREMISES NETWORK AND ACCESS EQUIPMENT; PART 3: CPS TYPE 1 IMPLEMENTATION DETAILS |
BS 646(1958) : 1958 | SPECIFICATION FOR CARTRIDGE FUSE-LINKS (RATED UP TO 5 AMPERES) FOR A.C. AND D.C. SERVICE |
BS 1363-4(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 4: SPECIFICATION FOR 13 A FUSED CONNECTION UNITS SWITCHED AND UNSWITCHED |
BS 6500:2000 | Electric cables. Flexible cords rated up to 300/500 V, for use with appliances and equipment intended for domestic, office and similar environments |
BS 6739:2009 | Code of practice for instrumentation in process control systems: installation design and practice |
BS 5546:2000 | Specification for installation of hot water supplies for domestic purposes, using gas-fired appliances of rated input not exceeding 70 kW |
BS 1363-3(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 3: SPECIFICATION FOR ADAPTORS |
BS 6896:2005 | Specification for installation of gas-fired overhead radiant heaters for industrial and commercial heating (2nd and 3rd family gases) |
TS 102 874-4 : 1.2.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); EXTERNAL COMMON POWER SUPPLY FOR CUSTOMER PREMISES NETWORK AND ACCESS EQUIPMENT; PART 4: CPS TYPE 2.B IMPLEMENTATION DETAILS |
15/30297238 DC : 0 | BS 1363-4 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 4: SPECIFICATION FOR 13 A FUSED CONNECTION UNITS SWITCHED AND UNSWITCHED |
14/30270861 DC : 0 | BS 4163 - HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN EDUCATIONAL AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
BS 1363-5:2008 | 13 A plugs, socket-outlets, adaptors and connection units Specification for fused conversion plugs |
CEI EN 62606 : 2014 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
CSA C22.2 No. 60950-1 :2007 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 60950-1 : 2007 : INC : AMD 1 : 2011 : R2012 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 60950-1 : 2007 : INC : AMD 2 : 2014 : R201200 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 60950-1 : 2007 : R2012 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 60950-1 : 2007 : INC : UPD 1 : 2011 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 60950-1 : 2007 : INC : AMD 2 : 2014 : R2016 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS |
I.S. EN 61009-1:2012 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
BS 7540-3:2005 | Electric cables. Guide to use for cables with a rated voltage not exceeding 450/750 V National standard cables not included in HD 21 and HD 22 |
15/30297240 DC : 0 | BS 1363-5 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 5: SPECIFICATION FOR FUSED CONVERSION PLUGS |
TS 102 874-2 : 1.1.1 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); EXTERNAL COMMON POWER SUPPLY FOR CUSTOMER PREMISES NETWORK AND ACCESS EQUIPMENT; PART 2: INTEGRATED BROADBAND CABLE AND TELEVISION NETWORKS |
08/30136724 DC : DRAFT MAY 2008 | BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE |
BS 1363-2(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 2: SPECIFICATION FOR 13 A SWITCHED AND UNSWITCHED SOCKET-OUTLETS |
BS 6396(2008) : 2008 | ELECTRICAL SYSTEMS IN OFFICE FURNITURE AND EDUCATIONAL FURNITURE - SPECIFICATION |
BS 6396:2008+A1:2015 | Electrical systems in office furniture and educational furniture. Specification |
BS 6396:2002 | Electrical systems in office furniture and office screens. Specification |
BS 5655-6:2002 | Lifts and service lifts Code of practice for the selection and installation of new lifts |
12/30268414 DC : 0 | BS 646 + A2 - SPECIFICATION. CARTRIDGE FUSE-LINKS (RATED UP TO 5 AMPERES) FOR A.C. AND D.C. SERVICE |
I.S. EN 62606:2013 | GENERAL REQUIREMENTS FOR ARC FAULT DETECTION DEVICES |
08/30177004 DC : DRAFT JULY 2008 | BS 6396 - ELECTRICAL SYSTEMS IN OFFICE FURNITURE AND OFFICE SCREENS - SPECIFICATION |
BS 7671(2001) : 2001 AMD 14905 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS EN 62606:2013 | General requirements for arc fault detection devices |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 4163:2007 | HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
BS 4163:2014 | Health and safety for design and technology in educational and similar establishments. Code of practice |
BS EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems Principles, requirements and tests |
BS 1363-2(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 2: SPECIFICATION FOR 13 A SWITCHED AND UNSWITCHED SOCKET-OUTLETS |
BS EN 61140 : 2002 | PROTECTION AGAINST ELECTRIC SHOCK - COMMON ASPECTS FOR INSTALLATION AND EQUIPMENT |
BS EN 60695-10-2:2014 | Fire hazard testing Abnormal heat. Ball pressure test method |
BS 6004:2000 | Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring |
BS 5901:1980 | Method of test for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions |
BS 4662:1970 | Specification for boxes for the enclosure of electrical accessories |
BS EN 61032:1998 | Protection of persons and equipment by enclosures. Probes for verification |
BS EN 60112 : 2003 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
BS 1363-4(1995) : 1995 | 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 4: SPECIFICATION FOR 13 A FUSED CONNECTION UNITS SWITCHED AND UNSWITCHED |
BS EN 61180-1:1995 | High-voltage test techniques for low-voltage equipment Definitions, test and procedure requirements |
BS EN 60695-2-11:2014 | Fire hazard testing Glowing/hot-wire based test methods. Glow-wire flammability test method for end-products (GWEPT) |
BS 5216:1991 | Specification for patented cold drawn steel wire for mechanical springs |
BS 6217:1981 | Guide to graphical symbols for use on electrical equipment |
BS 1362:1973 | Specification for general purpose fuse links for domestic and similar purposes (primarily for use in plugs) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.