Standard Practice for Continuous Sizing and Counting of Airborne Particles in Dust-Controlled Areas and Clean Rooms Using Instruments Capable of Detecting Single Sub-Micrometre and Larger Particles
Hardcopy , PDF
28-04-2021
English
04-11-2015
CONTAINED IN VOL. 15.03, 2015 Describes the determination of the particle concentration, by number, and the size distribution of airborne particles in dust-controlled areas and clean rooms, for particles in the size range of approximately 0.01 to 5.0 [mu]m.
Committee |
E 21
|
DocumentType |
Standard Practice
|
Pages |
6
|
ProductNote |
Reconfirmed 2015
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice covers the determination of the particle concentration, by number, and the size distribution of airborne particles in dust-controlled areas and clean rooms, for particles in the size range of approximately 0.01 to 5.0 μm. Particle concentrations not exceeding 3.5 × 106 particles/m 3 (100 000/ft3) are covered for all particles equal to and larger than the minimum size measured.
1.2This practice uses an airborne single particle counting device (SPC) whose operation is based on measuring the signal produced by an individual particle passing through the sensing zone. The signal must be directly or indirectly related to particle size.
Note 1:The SPC type is not specified here. The SPC can be a conventional optical particle counter (OPC), an aerodynamic particle sizer, a condensation nucleus counter (CNC) operating in conjunction with a diffusion battery or differential mobility analyzer, or any other device capable of counting and sizing single particles in the size range of concern and of sampling in a cleanroom environment.
1.3Individuals performing tests in accordance with this practice shall be trained in use of the SPC and shall understand its operation.
1.4Since the concentration and the particle size distribution of airborne particles are subject to continuous variations, the choice of sampling probe configuration, locations and sampling times will affect sampling results. Further, the differences in the physical measurement, electronic and sample handling systems between the various SPCs and the differences in physical properties of the various particles being measured can contribute to variations in the test results. These differences should be recognized and minimized by using a standard method of primary calibration and by minimizing variability of sample acquisition procedures.
1.5Sample acquisition procedures and equipment may be selected for specific applications based on varying cleanroom class levels. Firm requirements for these selections are beyond the scope of this practice; however, sampling practices shall be stated that take into account potential spatial and statistical variations of suspended particles in clean rooms.
Note 2:General references to cleanroom classifications follow Federal Standard 209E, latest revision. Where airborne particles are to be characterized in dust-controlled areas that do not meet these classifications, the latest revision of the pertinent specification for these areas shall be used.
1.6The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only and are not considered standard.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 8.
ASTM E 2217 : 2012 : R2019 | Standard Practice for Design and Construction of Aerospace Cleanrooms and Contamination Controlled Areas |
ASTM E 2042/E2042M : 2009 : R2016 | Standard Practice for Cleaning and Maintaining Controlled Areas and Clean Rooms |
ASTM E 1548 : 2009 : R2017 | Standard Practice for Preparation of Aerospace Contamination Control Plans |
ASTM E 1235 : 2012 : R2020 : EDT 1 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft |
ASTM E 2352 : 2019 | Standard Practice for Aerospace Cleanrooms and Associated Controlled Environments—Cleanroom Operations |
ASTM E 1731 : 2011 : R2018 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves |
ASTM F 1977 : 2004 : R2017 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System |
ASTM F 2299/F2299M : 2003 : R2017 | Standard Test Method for Determining the Initial Efficiency of Materials Used in Medical Face Masks to Penetration by Particulates Using Latex Spheres |
ASTM E 1560 : 2018 | Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers |
ASTM D 1356 : 2015 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM F 328 : 1998 | Standard Practice for Calibration of an Airborne Particle Counter Using Monodisperse Spherical Particles |
ASTM F 649 : 2001 | Standard Practice for Secondary Calibration of Airborne Particle Counter Using Comparison Procedures (Withdrawn 2007) |
ISO 14644-2:2015 | Cleanrooms and associated controlled environments Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration |
ASTM D 1356 : 2017 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2015 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
FED-STD-209 Revision E:1992 | AIRBORNE PARTICULATE CLEANLINESS CLASSES IN CLEANROOMS AND CLEAN ZONES |
ASTM D 1356 : 2014 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2015 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2005 : R2010 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ISO 14644-1:2015 | Cleanrooms and associated controlled environments Part 1: Classification of air cleanliness by particle concentration |
ASTM D 1356 : 2020 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2000 : REV A | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2014 : REV B | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2014 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
ASTM D 1356 : 2005 | Standard Terminology Relating to Sampling and Analysis of Atmospheres |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.