ASTM F 2977 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Small Punch Testing of Polymeric Biomaterials Used in Surgical Implants
Hardcopy , PDF
03-06-2020
English
01-06-2013
CONTAINED IN VOL. 13.02, 2015 Defines the determination of mechanical behavior of polymeric biomaterials by small punch testing of miniature disk specimens (0.5 mm in thickness and 6.4 mm in diameter).
Committee |
F 04
|
DocumentType |
Test Method
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This test method covers the determination of mechanical behavior of polymeric biomaterials by small punch testing of miniature disk specimens (0.5 mm in thickness and 6.4 mm in diameter). The test method has been established for characterizing surgical materials after ram extrusion or compression molding (1-3)2; for evaluating as-manufactured implants and sterilization method effects (4, 5); as well as for testing of implants that have been retrieved (explanted) from the human body (6, 7).
1.2The results of the small punch test, namely the peak load, ultimate displacement, ultimate load, and work to failure, provide metrics of the yielding, ultimate strength, ductility, and toughness under multiaxial loading conditions. Because the mechanical behavior can be different when loaded under uniaxial and multiaxial loading conditions (8), the small punch test provides a complementary mechanical testing technique to the uniaxial tensile test. However, it should be noted that the small punch test results may not correlate with uniaxial tensile test results.
1.3In addition to its use as a research tool in implant retrieval analysis, the small punch test can be used as a laboratory screening test to evaluate new materials with minimal material waste (1).
1.4The small punch test has been applied to other polymers, including polymethyl methacrylate (PMMA) bone cement, polyacetal, and high density polyethylene (HDPE), ultra high molecular weight polyethylene (UHMWPE), and polyetheretherketone (PEEK) (2, 3, 5, 10, 11). This standard outlines general guidelines for the small punch testing of implantable polymers.
ASTM F 561 : 2019 | Standard Practice for Retrieval and Analysis of Medical Devices, and Associated Tissues and Fluids |
ASTM F 2759 : 2019 | Standard Guide for Assessment of the Ultra-High Molecular Weight Polyethylene (UHMWPE) Used in Orthopedic and Spinal Devices |
ASTM F 2003 : 2002 | Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air |
ASTM F 1714 : 1996 : R2008 | Standard Guide for Gravimetric Wear Assessment of Prosthetic Hip Designs in Simulator Devices |
ASTM F 2102 : 2001 : EDT 1 | Standard Guide for Evaluating the Extent of Oxidation in Ultra-High-Molecular-Weight Polyethylene Fabricated Forms Intended for Surgical Implants |
ASTM F 2003 : 2002 : R2015 | Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air |
ASTM F 1715 : 2000 | Standard Guide for Wear Assessment of Prosthetic Knee Designs in Simulator Devices |
ASTM E 83 : 2016 : REDLINE | Standard Practice for Verification and Classification of Extensometer Systems |
ASTM F 2003 : 2002 : R2008 | Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air |
ASTM F 2102 : 2006 : EDT 1 | Standard Guide for Evaluating the Extent of Oxidation in Ultra-High-Molecular-Weight Polyethylene Fabricated Forms Intended for Surgical Implants |
ASTM F 1714 : 1996 : R2002 | Standard Guide for Gravimetric Wear Assessment of Prosthetic Hip-Designs in Simulator Devices |
ASTM F 1714 : 1996 : R2013 | Standard Guide for Gravimetric Wear Assessment of Prosthetic Hip Designs in Simulator Devices |
ASTM F 2102 : 2017 | Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants |
ASTM F 1714 : 1996 : R2018 | Standard Guide for Gravimetric Wear Assessment of Prosthetic Hip Designs in Simulator Devices |
ASTM F 2102 : 2017 : REDLINE | Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants |
ASTM F 1714 : 1996 | Standard Guide for Gravimetric Wear Assessment of Prosthetic Hip-Designs in Simulator Devices |
ASTM D 695 : 2015 : REDLINE | Standard Test Method for Compressive Properties of Rigid Plastics |
ASTM F 2102 : 2013 | Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants |
ASTM F 2102 : 2001 | Standard Guide for Evaluating the Extent of Oxidation in Ultra-High-Molecular-Weight Polyethylene Fabricated Forms Intended for Surgical Implants |
ASTM F 2003 : 2000 | Standard Guide for Accelerated Aging of Ultra-High Molecular Weight Polyethylene |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.