Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM F 2433 : 2005 : R2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Determining Thermoplastic Pipe Wall Stiffness

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-08-2009

$122.77
Including GST where applicable

CONTAINED IN VOL. 08.04, 2017 Specifies the determination of the load-deflection behavior of thermoplastic pipe wall sections under parallel plate loading conditions.

Committee
F 17
DocumentType
Test Method
Pages
6
ProductNote
Reconfirmed 2009
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This test method covers the determination of the load-deflection behavior of thermoplastic pipe wall sections under parallel plate loading conditions.

Note 1—These are not full pipe section tests, but pipe wall segment tests. The results of these tests will be different from pipe stiffness tests per Test Method D2412, although they may be proportional. This test provides quite different information, including , stress relaxation under constant strain, and comparisons of the function and stiffness of different pipe wall designs or materials.

1.2 This test method covers a loading test for determining the wall stiffness of a thermoplastic-pipe wall under a combined load of bending and compression. Changes in pipe wall profile geometry under load may also be determined.

1.3 This test method covers thermoplastic pipe.

1.4 The characteristics determined by this test method are wall stiffness and changes in profile wall dimensions at specific deformations.

1.5 The characteristics determined by this test method are wall stiffness, profile wall efficiency, and for some wall elements stability at specific Strain levels.

1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.7 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D 618 : 2013 : REDLINE Standard Practice for Conditioning Plastics for Testing
AASHTO M 294 : 2015 SPECIFICATION FOR CORRUGATED POLYETHYLENE PIPE, 300- TO 1500-MM (12- TO 60-IN.) DIAMETER
AASHTO M 252 : 2009 SPECIFICATION FOR CORRUGATED POLYETHYLENE DRAINAGE PIPE
ASTM D 2122 : 2016 : REDLINE Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
ASTM D 695 : 2015 : REDLINE Standard Test Method for Compressive Properties of Rigid Plastics

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.