CONTAINED IN VOL. 13.01, 2015 Specifies the chemical, mechanical, and metallurgical requirements for wrought annealed titanium-6aluminum-4vanadium alloy (UNS R56400) to be used in the manufacture of surgical implants.
Committee |
F 04
|
DocumentType |
Redline
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This specification covers the chemical, mechanical, and metallurgical requirements for wrought annealed titanium-6aluminum-4vanadium alloy (UNS R56400) to be used in the manufacture of surgical implants.
1.2Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
I.S. EN ISO 5832-3:2016 | IMPLANTS FOR SURGERY - METALLIC MATERIALS - PART 3: WROUGHT TITANIUM 6-ALUMINIUM 4-VANADIUM ALLOY (ISO 5832-3:2016) |
ASTM F 2146 : 2013 : REDLINE | Standard Specification for Wrought Titanium-3Aluminum-2.5Vanadium Alloy Seamless Tubing for Surgical Implant Applications (UNS R56320) |
ASTM F 2068 : 2015 : REDLINE | Standard Specification for Femoral Prostheses—Metallic Implants |
ASTM F 2665 : 2009 | Standard Specification for Total Ankle Replacement Prosthesis |
ASTM F 1713 : 2008 : R2013 | Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130) |
ASTM F 2665 : 2009 : R2014 | Standard Specification for Total Ankle Replacement Prosthesis |
ASTM F 620 : 2011 | Standard Specification for Titanium Alloy Forgings for Surgical Implants in the Alpha Plus Beta Condition |
NBR 15719 : 2016 | IMPLANTS FOR ORTHOPEDICS - HIP JOINT PROSTHESES - SPECIFICATION FOR ACETABULAR PROSTHESES |
DIN EN ISO 5832-3:2015-06 (Draft) | IMPLANTS FOR SURGERY - METALLIC MATERIALS - PART 3: WROUGHT TITANIUM 6-ALUMINIUM 4-VANADIUM ALLOY (ISO 5832-3:2016) |
ASTM F 3302 : 2018 | Standard for Additive Manufacturing – Finished Part Properties – Standard Specification for Titanium Alloys via Powder Bed Fusion |
ASTM F 2924 : 2014 : REDLINE | Standard Specification for Additive Manufacturing Titanium-6 Aluminum-4 Vanadium with Powder Bed Fusion |
ASTM F 2887 : 2017 : REDLINE | Standard Specification for Total Elbow Prostheses |
ASTM F 620 : 2011 : R2015 | Standard Specification for Titanium Alloy Forgings for Surgical Implants in the Alpha Plus Beta Condition |
ASTM F 2027 : 2016 : REDLINE | Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
ISO 5832-3:2016 | Implants for surgery Metallic materials Part 3: Wrought titanium 6-aluminium 4-vanadium alloy |
ASTM F 1713 : 2008 | Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130) |
ASTM F 384 : 2017 : REDLINE | Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices |
ASTM F 543 : 2017 : REDLINE | Standard Specification and Test Methods for Metallic Medical Bone Screws |
ASTM F 2885 : 2017 : REDLINE | Standard Specification for Metal Injection Molded Titanium-6Aluminum-4Vanadium Components for Surgical Implant Applications |
UNE-EN ISO 5832-3:2017 | Implants for surgery - Metallic materials - Part 3: Wrought titanium 6-aluminium 4-vanadium alloy (ISO 5832-3:2016) |
ASTM F 2091 : 2015 : REDLINE | Standard Specification for Acetabular Prostheses |
ASTM F 2083 : 2012 : REDLINE | Standard Specification for Knee Replacement Prosthesis |
EN ISO 5832-3:2016 | Implants for surgery - Metallic materials - Part 3: Wrought titanium 6-aluminium 4-vanadium alloy (ISO 5832-3:2016) |
NBR 15676-1 : 2017 | ORTHOPEDIC IMPLANTS - METALLIC BONE PLATES - PART 1: REQUIREMENTS |
ASTM E 2371 : 2013 | Standard Test Method for Analysis of Titanium and Titanium Alloys by Direct Current Plasma and Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-Based Test Methodology) |
SAE J 1086 : 2012 | NUMBERING METALS AND ALLOYS |
SAE AMS 4911 : 2014 | TITANIUM ALLOY, SHEET, STRIP, AND PLATE, 6AL - 4 V, ANNEALED |
ISO 6892:1998 | Metallic materials Tensile testing at ambient temperature |
ISO 5832-3:2016 | Implants for surgery Metallic materials Part 3: Wrought titanium 6-aluminium 4-vanadium alloy |
ASTM F 136 : 2013 : REDLINE | Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401) |
SAE AMS 4965 : 2014 | TITANIUM ALLOY, BARS, WIRE, FORGINGS, AND RINGS, 6.0AL 4.0V, SOLUTION HEAT TREATED AND AGED |
ASTM E 1409 : 2013 : REDLINE | Standard Test Method for Determination of Oxygen and Nitrogen in Titanium and Titanium Alloys by Inert Gas Fusion |
SAE AMS 2631 : 2011 | ULTRASONIC INSPECTION, TITANIUM AND TITANIUM ALLOY BAR, BILLET AND PLATE |
SAE AMS 2249 : 2013 | CHEMICAL CHECK ANALYSIS LIMITS, TITANIUM AND TITANIUM ALLOYS |
ASTM E 527 : 2016 : REDLINE | Standard Practice for Numbering Metals and Alloys in the Unified Numbering System (UNS) |
ISO 9001:2015 | Quality management systems — Requirements |
ASTM E 290 : 2014 : REDLINE | Standard Test Methods for Bend Testing of Material for Ductility |
ASTM E 8/E8M : 2016-09 | TEST METHODS FOR TENSION TESTING OF METALLIC MATERIALS |
SAE AMS 4928 : 2016 | TITANIUM ALLOY BARS, WIRE, FORGINGS, RINGS, AND DRAWN SHAPES, 6AL - 4V, ANNEALED |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.