Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM E 2813 : 2012 : EDT 1

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Building Enclosure Commissioning

Available format(s)

Hardcopy , PDF

Superseded date

10-05-2024

Superseded by

ASTM E 2813 : 2018

Language(s)

English

Published date

01-02-2012

$135.86
Including GST where applicable

CONTAINED IN VOL. 04.12, 2015 Defines a concise, authoritative, and technically sound practice for Building Enclosure Commissioning (BECx) that establishes two levels of BECx: Fundamental and Enhanced

Committee
E 06
DocumentType
Standard Practice
Pages
19
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This practice is intended to serve as a concise, authoritative, and technically sound practice for Building Enclosure Commissioning (BECx) that establishes two levels of BECx: Fundamental and Enhanced (refer also to Section 4).

1.2The BECx process as defined in this practice includes the following phases and sub-phases:

1.2.1Pre-design,

1.2.2Design,

1.2.2.1Schematic Design,

1.2.2.2Design Development,

1.2.2.3Construction Documentation,

1.2.3Pre-Construction,2

1.2.4Construction, and

1.2.5Occupancy and Operations.

1.3This practice includes a mandatory OPR Development Guideline (Annex A1) and requires the development of an OPR for both Fundamental and Enhanced BECx that addresses, at a minimum, the performance attributes and metrics included in Annex A1 of this practice.

1.4This practice includes mandatory BECx Performance Testing Requirements (Annex A2) approved for use with this practice to evaluate the performance and durability of enclosure materials, components, systems, and assemblies.

1.5This practice mandates independent, third-party design peer review during the Design Phase of both Fundamental and Enhanced BECx.

1.6This practice recognizes that the OPR for exterior enclosure performance and environmental separation may exceed the baseline requirements of applicable building codes and standards and provides guidance for the development of an OPR based on the following attributes as defined in Annex A1 of this practice:

1.6.1Energy,

1.6.2Environment,

1.6.3Safety,

1.6.4Security,

1.6.5Durability,

1.6.6Sustainability, and

1.6.7Operation.

1.7The terms “building enclosure” and “enclosure” as they appear in this practice refer collectively to all materials, components, systems, and assemblies intended to provide shelter and environmental separation between interior and exterior, or between two or more environmentally distinct interior spaces in a building or structure.

1.8This practice establishes that the Building Enclosure Commissioning Provider (BECxP) refers specifically to the individual retained by the Owner to develop, manage, and be in responsible charge of the BECx process, including individual members and technical specialists that may comprise the BECx team (see 4.2).

1.9The role and responsibilities of the BECxP as defined by this practice are not intended to supersede or otherwise replace the contractual obligations reserved specifically for the parties responsible for the design and construction of a building or structure, nor the duties that may otherwise be assigned to those parties by applicable regulatory or statutory law.

1.10This practice is not intended to warrant or otherwise guarantee the as-built or in-service durability, or both, and performance of enclosure materials, components, systems, and assemblies.

1.11The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.12This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 2947 : 2016 : REV A Standard Guide for Building Enclosure Commissioning

ASTM E 1050 : 2012 : REDLINE Standard Test Method for Impedance and Absorption of Acoustical Materials Using a Tube, Two Microphones and a Digital Frequency Analysis System
ASTM C 423 : 2017 : REDLINE Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM C 510 : 2016 : REDLINE Standard Test Method for Staining and Color Change of Single- or Multicomponent Joint Sealants
ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ASHRAE 101 : 1981 APPLICATION OF INFRARED SENSING DEVICES TO THE ASSESSMENT OF BUILDING HEAT LOSS CHARACTERISTICS
ASHRAE GUIDELINE 0 : 2013 THE COMMISSIONING PROCESS
ASTM E 1105 : 2015 : REDLINE Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference
ASTM E 1996 : 2017 : REDLINE Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
ASTM C 1294 : 2015 : REDLINE Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials
ASTM E 576 : 2014 : REDLINE Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units in the Vertical Position
ASTM D 4541 : 2017 : REDLINE Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers
ANSI S12.60 : 0 ACOUSTICAL PERFORMANCE CRITERIA, DESIGN REQUIREMENTS, AND GUIDELINES FOR SCHOOLS
ASHRAE 90.1 : 1999 ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
ASTM C 1193 : 2016 : REDLINE Standard Guide for Use of Joint Sealants
ASTM E 2570 : 2007 Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
ASTM E 1503 : 2014 : REDLINE Standard Test Method for Conducting Outdoor Sound Measurements Using a Digital Statistical Sound Analysis System
ASTM E 903 : 2012 Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres
ASTM E 795 : 2016 : REDLINE Standard Practices for Mounting Test Specimens During Sound Absorption Tests
ASTM C 1549 : 2016 : REDLINE Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer
ASTM C 1246 : 2017 : REDLINE Standard Test Method for Effects of Heat Aging on Weight Loss, Cracking, and Chalking of Elastomeric Sealants After Cure
ASTM E 331 : 2000 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
ASTM E 2359 : 2006 Standard Test Method for Field Pull Testing of an In-Place Exterior Insulation and Finish System Clad Wall Assembly
ASTM C 732 : 2017 : REDLINE Standard Test Method for Aging Effects of Artificial Weathering on Latex Sealants
ASTM E 2353 : 2016 : REDLINE Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
ASTM E 2649 : 2012 Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy
ASTM E 2179 : 2003 Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors
EN 1063:1999 Glass in building - Security glazing - Testing and classification of resistance against bullet attack
ASTM C 1371 : 2015 : REDLINE Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers
ASTM E 1425 : 2014 : REDLINE Standard Practice for Determining the Acoustical Performance of Windows, Doors, Skylight, and Glazed Wall Systems
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
ASTM C 1087 : 2016 : REDLINE Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems
ASTM E 488 : 1996 Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements
ASTM E 1186 : 2017 : REDLINE Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems
ASTM E 1014 : 2012 : REDLINE Standard Guide for Measurement of Outdoor A-Weighted Sound Levels
ASTM E 1980 : 2011 Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surfaces
ASTM C 1279 : 2013 : REDLINE TEST METHOD FOR NON-DESTRUCTIVE PHOTOELASTIC MEASUREMENT OF EDGE AND SURFACE STRESSES IN ANNEALED, HEAT-STRENGTHENED, AND FULLY TEMPERED FLAT GLASS
ASTM E 997 : 2015 : REDLINE Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing
ASTM E 2178 : 2013 : REDLINE Standard Test Method for Air Permeance of Building Materials
CGSB 149-GP-2MP : 1986 MANUAL FOR THERMOGRAPHIC ANALYSIS OF BUILDING ENCLOSURES
CSA A123.21 : 2014 STANDARD TEST METHOD FOR THE DYNAMIC WIND UPLIFT RESISTANCE OF MEMBRANE-ROOFING SYSTEMS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more