1.1This guide covers building design, construction, commissioning, operation, and maintenance.
1.2This guide addresses the need for systematic evaluation of factors that can result in moisture-induced damage to a building or its components. Although of great potential importance, serviceability issues which are often, but not necessarily, related to physical damage of the building or its components (for example, indoor air quality or electrical safety) are not directly addressed in this guide.
1.3The emphasis of this guide is on low-rise buildings. Portions of this guide; in particular Sections 5, 6, and 7; may also be applicable to high-rise buildings.
1.4This guide is not intended for direct use in codes and specifications. It does not attempt to prescribe acceptable limits of damage. Buildings intended for different uses may have different service life expectancies, and expected service lives of different components within a given building often differ. Furthermore, some building owners may be satisfied with substantially shorter service life expectancies of building components or of the entire building than other building owners. Lastly, the level of damage that renders a component unserviceable may vary with the type of component, the degree to which failure of the component is critical (for example, whether failure constitutes a life-safety hazard), and the judgement (that is, tolerance for damage) of the building owner. For the reasons stated in this paragraph, prescribing limits of damage would require listing many pages of exceptions and qualifiers and is beyond the scope of this guide.
1.5The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6This standard does not purport to address the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM E 1105 : 2015 | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
ASTM C 168 : 2019 | Standard Terminology Relating to Thermal Insulation |
ASTM E 1677 : 2019 | Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls |
ASTM C 1193 : 2016 : R2023 | Standard Guide for Use of Joint Sealants |
ASTM E 1643 : 2024 | Standard Practice for Selection, Design, Installation, and Inspection of Water Vapor Retarders Used in Contact with Earth or Granular Fill Under Concrete Slabs |
ASTM C 1193 : 2016 | Standard Guide for Use of Joint Sealants |
ASTM D 1079 : 2020 | Standard Terminology Relating to Roofing and Waterproofing |
ASTM C 717 : 2019 | Standard Terminology of Building Seals and Sealants |
ASTM E 2112 : 2023 | Standard Practice for Installation of Exterior Windows, Doors and Skylights |
ASTM E 1105 : 2015 : R2023 | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
ASTM C 168 : 2024 | Standard Terminology Relating to Thermal Insulation |
ASTM E 632 : 1982 : R1996 | Standard Practice for Developing Accelerated Tests to Aid Prediction of the Service Life of Building Components and Materials (Withdrawn 2005) |
ASTM E 631 : 2015 : R2024 | Standard Terminology of Building Constructions |
ASTM E 1643 : 2018 : REV A | Standard Practice for Selection, Design, Installation, and Inspection of Water Vapor Retarders Used in Contact with Earth or Granular Fill Under Concrete Slabs |
ASTM E 1745 : 2017 | Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM E 2136 : 2004 : R2013 | Standard Guide for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings—Durability (Withdrawn 2022) |
ASTM E 631 : 2015 | Standard Terminology of Building Constructions |
ASTM E 1677 : 2023 | Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls |
ASTM E 331 : 2000 : R2023 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM D 1079 : 2024 | Standard Terminology Relating to Roofing and Waterproofing |
ASTM E 1745 : 2017 : R2023 | Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM C 717 : 2024 | Standard Terminology of Building Seals and Sealants |
ASTM C 168 : 2022 | Standard Terminology Relating to Thermal Insulation |
ASTM E 331 : 2000 : R2016 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM E 2112 : 2019 : REV C | Standard Practice for Installation of Exterior Windows, Doors and Skylights |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.