ASTM E 2339 : 2015 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)
18-06-2022
English
21-12-2015
CONTAINED IN VOL. 03.03, 2017 Specifies the interoperability of NDE imaging and data acquisition equipment by specifying the image data in commonly accepted terms.
Committee |
E 07
|
DocumentType |
Redline
|
Pages |
11
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This practice facilitates the interoperability of NDE imaging and data acquisition equipment by specifying the image data in commonly accepted terms. This practice represents a harmonization of NDE imaging systems, or modalities, with the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival. In addition, this practice will provide a standard set of industrial NDE specific information object definitions, which travel beyond the scope of standard DICOM modalities. The goal of this practice is to provide a standard by which NDE image/signal data may be displayed on by any system conforming to the ASTM DICONDE format, regardless of which NDE modality was used to acquire the data.
1.2This practice has been developed to overcome the issues that arise when archiving or analyzing the data from a variety of NDE techniques, each using proprietary data acquisition systems. As data acquisition modalities evolve, data acquired in the past must remain decipherable. This practice proposes an image data file format in such a way that all the technique parameters, along with the image file, are preserved, regardless of changes in NDE technology. This practice will also permit the viewing of a variety of image types (CT, CR, Ultrasonic, Infrared and Eddy Current) on a single workstation, maintaining all of the pertinent technique parameters along with the image file. This practice addresses the exchange of digital information between NDE imaging equipment.
1.3This practice does not specify:
1.3.1A complete description of all the information necessary to implement the DICONDE standard for an imaging modality. This document must be used in conjunction with one of the method-specific DICONDE Standard Practice documents to completely describe all the requirements necessary to implement the DICONDE standard for an imaging modality. See Section 2.1 of this document for a current list of the method-specific standard practice documents.
1.3.2A testing or validation procedure to assess an implementation's conformance to the standard.
1.3.3The implementation details of any features of the standard on a device claiming conformance.
1.3.4The overall set of features and functions to be expected from a system implemented by integrating a group of devices each claiming DICONDE or DICOM conformance.
1.4Although this practice contains no values that require units, it does describe methods to store and communicate data that do require units to be properly interpreted. The SI units required by this practice are to be regarded as standard. No other units of measurement are included in this standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2663 : 2014-12 | PRACTICE FOR DIGITAL IMAGING AND COMMUNICATION IN NONDESTRUCTIVE EVALUATION (DICONDE) FOR ULTRASONIC TEST METHODS |
ASTM E 1161 : 2009 | Standard Practice for Radiologic Examination of Semiconductors and Electronic Components |
ASTM E 2007 : 2010 : R2016 | Standard Guide for Computed Radiography |
ASTM E 3147 : 2018 | Standard Practice for Evaluating DICONDE Interoperability of Nondestructive Testing and Inspection Systems |
NEMA PS3.6 : 2017A | DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 6: DATA DICTIONARY |
ASTM E 1161 : 2009 : R2014 | Standard Practice for Radiologic Examination of Semiconductors and Electronic Components |
SAE AS 6171 : 2016 | TEST METHODS STANDARD; GENERAL REQUIREMENTS, SUSPECT/COUNTERFEIT, ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL PARTS |
SAE AS 6171/5 : 2016 | TECHNIQUES FOR SUSPECT/COUNTERFEIT EEE PARTS DETECTION BY RADIOLOGICAL TEST METHODS |
ASTM E 2698 : 2010 | Standard Practice for Radiological Examination Using Digital Detector Arrays |
ASTM E 1255 : 2016 : REDLINE | Standard Practice for Radioscopy |
ASTM E 2007 : 2010 | Standard Guide for Computed Radiography |
ASTM E 1814 : 2014 : REDLINE | Standard Practice for Computed Tomographic (CT) Examination of Castings |
ASME Y14.46 : 2017 | PRODUCT DEFINITION FOR ADDITIVE MANUFACTURING |
NEMA 300 : 1988 | DIGITAL IMAGING AND COMMUNICATIONS |
ASTM E 2663 : 2014-12 | PRACTICE FOR DIGITAL IMAGING AND COMMUNICATION IN NONDESTRUCTIVE EVALUATION (DICONDE) FOR ULTRASONIC TEST METHODS |
NEMA PS 3.1:2017A | DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 1: INTRODUCTION AND OVERVIEW |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.