ASTM E 2339 : 2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Superseded by

ASTM E 2339 : 2011

Language(s)

English

Published date

01-06-2010

$122.77
Including GST where applicable

Committee
E 07
DocumentType
Standard Practice
Pages
9
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This practice facilitates the interoperability of NDE imaging and data acquisition equipment by specifying the image data in commonly accepted terms. This practice represents a harmonization of NDE imaging systems, or modalities, with the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival. In addition, this practice will provide a standard set of industrial NDE specific information object definitions, which travel beyond the scope of standard DICOM modalities. The goal of this practice is to provide a standard by which NDE image/signal data may be displayed on by any system conforming to the ASTM DICONDE format, regardless of which NDE modality was used to acquire the data.

1.2 This practice has been developed to overcome the issues that arise when archiving or analyzing the data from a variety of NDE techniques, each using proprietary data acquisition systems. As data acquisition modalities evolve, data acquired in the past must remain decipherable. This practice proposes an image data file format in such a way that all the technique parameters, along with the image file, are preserved, regardless of changes in NDE technology. This practice will also permit the viewing of a variety of image types (CT, CR, Ultrasonic, Infrared and Eddy Current) on a single workstation, maintaining all of the pertinent technique parameters along with the image file. This practice addresses the exchange of digital information between NDE imaging equipment.

1.3 This practice does not specify:

1.3.1 A testing or validation procedure to assess an implementation's conformance to the standard.

1.3.2 The implementation details of any features of the standard on a device claiming conformance.

1.3.3 The overall set of features and functions to be expected from a system implemented by integrating a group of devices each claiming DICONDE or DICOM conformance.

1.4 Although this practice contains no values that require units, it does describe methods to store and communicate data that do require units to be properly interpreted. The SI units required by this practice are to be regarded as standard. No other units of measurement are included in this standard.

ASTM E 2738 : 2018 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods
ASTM E 2007 : 2010 : R2016 Standard Guide for Computed Radiography
ASTM E 1161 : 2009 : R2014 Standard Practice for Radiologic Examination of Semiconductors and Electronic Components
ASTM E 1734 : 2016 : REV A Standard Practice for Radioscopic Examination of Castings
ASTM E 2699 : 2018 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods
ASTM E 3147 : 2018 Standard Practice for Evaluating DICONDE Interoperability of Nondestructive Testing and Inspection Systems
ASTM E 1672 : 2012 Standard Guide for Computed Tomography (CT) System Selection
ASTM E 2033 : 2017 Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)
ASTM E 3169 : 2018 Standard Guide for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)
ASTM E 1814 : 2014 Standard Practice for Computed Tomographic (CT) Examination of Castings
ASTM E 2698 : 2018 : EDT 1 Standard Practice for Radiographic Examination Using Digital Detector Arrays
ASTM E 1255 : 2016 Standard Practice for Radioscopy
ASTM E 2767 : 2013 : R2018 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for X-ray Computed Tomography (CT) Test Methods

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more