ASTM E 1913 : 2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Conducting Static, Axenic, 14-Day Phytotoxicity Tests in Test Tubes with the Submersed Aquatic Macrophyte, Myriophyllum sibiricum Komarov
Hardcopy , PDF
11-11-2014
English
01-04-2004
CONTAINED IN VOL. 11.06, 2012 Assesses the potential phytotoxicity of a test material added to a sterile liquid growth medium on a certain species of freshwater submersed macrophyte. To determine the direct effect of the test chemical upon individual parameters, a sterile system is recommended. The procedures apply to most chemicals, either in formulations, individually, commercial products or known mixtures.
Committee |
E 47
|
DocumentType |
Guide
|
Pages |
15
|
ProductNote |
Reconfirmed 2004
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 Submersed rooted aquatic macrophytes are important components of aquatic systems. They contribute to primary productivity, improve water quality, cycle nutrients, generate oxygen, affect flow patterns, provide habitat and food for other organisms, and stabilize the sediment. These plants can be adversely affected when pesticides are sprayed to control aquatic weeds and algal blooms or when phytotoxic chemicals enter the waterway through atmospheric fallout, soil erosion, industrial effluent, sewage discharge, spills or drift from aerial or ground applications.
1.2 This guide is designed to give guidance for assessing the potential phytotoxicity of a test material added to a sterile liquid growth medium on a certain species of freshwater submersed macrophyte (
1.3 The procedures in this guide are applicable to most chemicals, either individually or in formulations, commercial products, or known mixtures. These procedures might be used to conduct tests for dependency on temperature, light, nutrients and pH. With appropriate modification, these procedures might be used to conduct tests for contaminated surface waters and aqueous effluents (see Guide E 1192). This static, axenic toxicity test might not be applicable to materials that contain microorganisms unless the sample can be filter sterilized without removing the toxicant. If the test materials are highly volatile, care should be taken to ensure that the test chambers are isolated. It might be necessary to replace the test material on a regular basis if the test material is rapidly biologically or chemically transformed in aqueous solution, or is removed from the test solutions in substantial quantities by the test chambers or organisms during the test. This toxicity test is not suitable for testing interactions between aquatic plants and other organisms, such as plant pathogens.
1.4 Results from the toxicity test outlined in this guide can be reported in terms of a 14-day IC25, IC50, or NOEC. This parameter may be based on several endpoints including inhibition of plant growth during the 14-day period, inhibition of shoot length, inhibition of root number and length, inhibition of fresh or dry weight (see Guide E 1415), inhibition of oxygen production, change in membrane permeability, and change in chlorophyll
1.5 This guide is arranged as follows:
Section | |
Referenced Documents | |
Terminology | |
Definitions | |
Definitions of Terms Specific to this Standard | |
Summary of Guide | |
Significance and Use | |
Interferences | |
Apparatus | |
Facilities | |
Test Chambers | |
Equipment | |
Cleaning | |
Acceptability | |
Reagents | |
Hazards | |
Nutrient Solution | |
Test Material | |
General | |
Test Concentrations | |
Stock Solutions | |
Controls | |
Test Organism | |
Recommended Species | |
Alternate Species | |
Culturing | |
Procedure | |
Experimental Design | |
Temperature | |
Illumination | |
Beginning the Test | |
Duration of Test | |
Evaluation of Test | |
Analytical Methodology | |
Calculations | |
Acceptability of Test | |
Report | |
Precision and Bias | |
Keywords | |
Appendixes | X1, X2 |
References |
1.6 The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This standard may involve hazardous materials, operations, and equipment. See Section for specific hazard statements.
ASTM E 1605 : 2018 : REV B | Standard Terminology Relating to Lead in Buildings |
ASTM E 1850 : 2004 : R2019 | Standard Guide for Selection of Resident Species as Test Organisms for Aquatic and Sediment Toxicity Tests |
ASTM D 1129 : 2013 : REDLINE | Standard Terminology Relating to Water |
ASTM E 1733 : 1995 | Standard Guide for Use of Lighting in Laboratory Testing |
ASTM E 1598 : 1994 | Standard Practice for Conducting Early Seedling Growth Tests (Withdrawn 2003) |
ASTM E 1847 : 1996 | Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines |
ASTM E 729 : 1996 | Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-