1.2This test method provides a means of determining the burning behavior of stacking chairs used in public occupancies by measuring specific fire-test responses when a stack of chairs is subjected to a specified flaming ignition source under well ventilated conditions.
1.4Test data are obtained describing the burning behavior following application of a specific ignition source, from ignition until all burning has ceased, a period of 1 h has elapsed, or flashover under test conditions appears inevitable.
1.5This test method does not provide information on the fire performance of stacked chairs under fire conditions other than those conditions specified in this test method. In particular, this test method does not apply to smoldering ignition by cigarettes. See 5.11 for further information.
1.6The rate of heat release of the burning test specimen is measured by an oxygen consumption method. See 5.11.4 for further information.
1.7Other measurements are the production of light-obscuring smoke and the concentrations of certain toxic gas species in the combustion gases. See 5.11.5 for further information.
1.9This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions..
1.10Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests. This test method may involve hazardous materials, operations, and equipment.
1.11Use the SI system of units in referee decisions; see IEEE/ASTM SI-10. The units given in parentheses are for information only.
ASTM E 2067 : 2015 | Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests |
ASTM E 2335 : 2017 | Standard Guide for Laboratory Monitors |
ASTM E 2102 : 2017 | Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater |
ASTM E 603 : 2017 | Standard Guide for Room Fire Experiments |
ASTM E 3020 : 2016 : REV A | Standard Practice for Ignition Sources |
ASTM E 176 : 2018 : REV A | Standard Terminology of Fire Standards |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.